User's Manual
Table Of Contents
- toc
- TRANSMITTAL INFORMATION
- INTRODUCTION
- 1. How to Use This Manual (TASK 23-15-30-99F-801- a 01)
- A. General (Subtask 23-15-30-99F-001- a 01)
- B. Observance of Manual Instructions (Subtask 23-15-30-99F-002-
- C. Symbols (Subtask 23-15-30-99F-003- a 01)
- D. Units of Measure (Subtask 23-15-30-99F-004- a 01)
- E. Illustration (Subtask 23-15-30-99F-005- a 01)
- F. Application of Maintenance Task Oriented Support System (MTOS
- 2. Customer Support (TASK 23-15-30-99F-802- a 01)
- 3. References (TASK 23-15-30-99F-803- a 01)
- 4. Acronyms and Abbreviations (TASK 23-15-30-99F-804- a 01)
- 5. Process Verification (TASK 23-15-30-99F-805- a 01)
- 1. How to Use This Manual (TASK 23-15-30-99F-801- a 01)
- DESCRIPTION AND OPERATION
- TESTING AND FAULT ISOLATION
- 1. Planning Data (TASK 23-15-30-99C-801- a 01)
- 2. Procedure (TASK 23-15-30-700-801- a 01)
- A. Job Setup (Subtask 23-15-30-810-001- a 01)
- B. BITE (Subtask 23-15-30-810-002- a 01)
- C. LEDs (Subtask 23-15-30-810-003- a 01)
- D. Self-Test (Subtask 23-15-30-810-004- a 01)
- E. Unit Software Load Procedure (Subtask 23-15-30-810-005- a 01)
- F. Fault Isolation (Subtask 23-15-30-810-006- a 01)
- G. Job Close-up (Subtask 23-15-30-810-007- a 01)
- CLEANING
- INSPECTION/CHECK
- 1. Planning Data (TASK 23-15-30-99C-803- a 01)
- 2. Procedure (TASK 23-15-30-210-801- a 01)
- A. Job Setup (Subtask 23-15-30-210-001- a 01)
- B. General Inspection/Check Procedure of the A350 SDU and SCM (S
- C. Instructions for Continued Airworthiness, FAR 25.1529 (Subtas
- D. Inspection/Check Schedule (Subtask 23-15-30-210-004- a 01)
- E. Unscheduled Maintenance (Subtask 23-15-30-210-005- a 01)
- F. Repair Requirements (Subtask 23-15-30-210-006- a 01)
- G. Job Close-up (Subtask 23-15-30-210-007- a 01)
- REPAIR
- FITS AND CLEARANCES
- SPECIAL TOOLS, FIXTURES, EQUIPMENT, AND CONSUMABLES
- REMOVAL
- INSTALLATION
- 1. Planning Data (TASK 23-15-30-99C-808- a 01)
- 2. Procedure (TASK 23-15-30-400-801- a 01)
- A. Job Setup (Subtask 23-15-30-400-001- a 01)
- B. Installation Data (Subtask 23-15-30-400-002- a 01)
- C. Unpacking and Inspecting Equipment (Subtask 23-15-30-400-003-
- D. Customer Acceptance Procedure (Subtask 23-15-30-400-004- a 01
- E. Installation Procedure (Subtask 23-15-30-400-005- a 01)
- F. Test (Subtask 23-15-30-400-006- a 01)
- G. Job Close-up (Subtask 23-15-30-400-007- a 01)
- STORAGE (INCLUDING TRANSPORTATION)
- REWORK
- APPENDIX A (RMA)
- tables
- Table 1. Applicable Components
- Table 2. Revision History
- Table 3. MTOSS Function Code Definitions
- Table 4. Verification Data
- Table 5. SDU Leading Particulars
- Table 6. SCM Leading Particulars
- Table 7. Equipment Description
- Table 8. SDU Rear Connector Pin Deviations
- Table 9. SCM D-Type Connector Pin Assignment
- Table 10. SDU Functional Interfaces
- Table 11. Special Tools, Fixtures, and Equipment
- Table 12. Consumables
- Table 13. LED Status Indicators Table
- Table 14. Special Tools, Fixtures, and Equipment
- Table 15. Consumables
- Table 16. Special Tools, Fixtures, and Equipment
- Table 17. Consumables
- Table 18. Special Tools, Fixtures, and Equipment
- Table 19. Consumables
- Table 20. Fits and Clearances
- Table 21. Thread Size and Torque Data
- Table 22. Final Torque Data
- Table 23. Special Tools, Fixtures, and Equipment
- Table 24. Consumable Materials
- Table 25. Special Tools, Fixtures, and Equipment
- Table 26. Consumable Materials
- Table 27. Special Tools, Fixtures, and Equipment
- Table 28. Consumables
ABBREVIATED COMPONENT MAINTENANCE MANUAL
1458-A-1101 / 1458-A-1300
(8) Table 7 lists the equipment covered by this manual.
Table 7. Equipment Description
Equipment PN Description/Notes
SDU 1458-A-1101 The central co
mmunications processing and control unit.
SCM 1458-A-1300 Stores installation configuration, ORT, ICAO, and USIM information.
B. Job
Setup Data (Subtask 23-15-30-99C-001-A01)
(1) The list that follows identifies Honeywell publications that are related to this section:
• Not applicable.
C. A35
0 SDU and SCM (Subtask 23-15-30-870-002-A01)
(1) SDU
(a) The SDU is the central communications processing and control unit, largely determining
the functionality of the complete SATCOM system. The signal-in-space parameters are
determined by the SDU in relation to modulation/demodulation, error correction, coding,
interleaving and data rates associated with the communication channel(s). The SDU
contains circuits for conversion of digital and/or analog inputs/outputs to/from RF, and
typically contains a PA module. The SDU interfaces at L-band with the HPA and DLNA
and also controls the antenna.
(b
)
Th
e SDU is capable of sending and receiving various data rates. The rate is dynamically
se
lected by the individual applications and by pragmatic assessment of current operating
c
onditions.
(2) SCM
(a) The SCM is an external peripheral of the SDU and provides a dedicated interface to the
SDU. It stores aircraft specific installation configuration, ORT configuration, and ICAO
identities. The SCM also contains four USIM that store subscriber information for the
SBB network.
(
b)
B
y storing configuration information independent of the SDU, the SCM facilitates
e
fficient SDU replacement. A new SDU that replaces a faulty SDU does not require any
c
onfiguration. All configuration information is obtained from the SCM.
(3) Refer to Figure 7 (GRAPHIC 23-15-30-99B-807-A01) for the A350 SATCOM Avionics System.
EFFECTIVITY
ALL
23-15-30
Page 35 of 70
5 Oct 2012
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Interim DRAFT for FCC Approval Purposes
Do Not Use for Maintenance
10-Feb-2013