User's Manual
Table Of Contents
- toc
- TRANSMITTAL INFORMATION
- INTRODUCTION
- 1. How to Use This Manual (TASK 23-15-30-99F-801- a 01)
- A. General (Subtask 23-15-30-99F-001- a 01)
- B. Observance of Manual Instructions (Subtask 23-15-30-99F-002-
- C. Symbols (Subtask 23-15-30-99F-003- a 01)
- D. Units of Measure (Subtask 23-15-30-99F-004- a 01)
- E. Illustration (Subtask 23-15-30-99F-005- a 01)
- F. Application of Maintenance Task Oriented Support System (MTOS
- 2. Customer Support (TASK 23-15-30-99F-802- a 01)
- 3. References (TASK 23-15-30-99F-803- a 01)
- 4. Acronyms and Abbreviations (TASK 23-15-30-99F-804- a 01)
- 5. Process Verification (TASK 23-15-30-99F-805- a 01)
- 1. How to Use This Manual (TASK 23-15-30-99F-801- a 01)
- DESCRIPTION AND OPERATION
- TESTING AND FAULT ISOLATION
- 1. Planning Data (TASK 23-15-30-99C-801- a 01)
- 2. Procedure (TASK 23-15-30-700-801- a 01)
- A. Job Setup (Subtask 23-15-30-810-001- a 01)
- B. BITE (Subtask 23-15-30-810-002- a 01)
- C. LEDs (Subtask 23-15-30-810-003- a 01)
- D. Self-Test (Subtask 23-15-30-810-004- a 01)
- E. Unit Software Load Procedure (Subtask 23-15-30-810-005- a 01)
- F. Fault Isolation (Subtask 23-15-30-810-006- a 01)
- G. Job Close-up (Subtask 23-15-30-810-007- a 01)
- CLEANING
- INSPECTION/CHECK
- 1. Planning Data (TASK 23-15-30-99C-803- a 01)
- 2. Procedure (TASK 23-15-30-210-801- a 01)
- A. Job Setup (Subtask 23-15-30-210-001- a 01)
- B. General Inspection/Check Procedure of the A350 SDU and SCM (S
- C. Instructions for Continued Airworthiness, FAR 25.1529 (Subtas
- D. Inspection/Check Schedule (Subtask 23-15-30-210-004- a 01)
- E. Unscheduled Maintenance (Subtask 23-15-30-210-005- a 01)
- F. Repair Requirements (Subtask 23-15-30-210-006- a 01)
- G. Job Close-up (Subtask 23-15-30-210-007- a 01)
- REPAIR
- FITS AND CLEARANCES
- SPECIAL TOOLS, FIXTURES, EQUIPMENT, AND CONSUMABLES
- REMOVAL
- INSTALLATION
- 1. Planning Data (TASK 23-15-30-99C-808- a 01)
- 2. Procedure (TASK 23-15-30-400-801- a 01)
- A. Job Setup (Subtask 23-15-30-400-001- a 01)
- B. Installation Data (Subtask 23-15-30-400-002- a 01)
- C. Unpacking and Inspecting Equipment (Subtask 23-15-30-400-003-
- D. Customer Acceptance Procedure (Subtask 23-15-30-400-004- a 01
- E. Installation Procedure (Subtask 23-15-30-400-005- a 01)
- F. Test (Subtask 23-15-30-400-006- a 01)
- G. Job Close-up (Subtask 23-15-30-400-007- a 01)
- STORAGE (INCLUDING TRANSPORTATION)
- REWORK
- APPENDIX A (RMA)
- tables
- Table 1. Applicable Components
- Table 2. Revision History
- Table 3. MTOSS Function Code Definitions
- Table 4. Verification Data
- Table 5. SDU Leading Particulars
- Table 6. SCM Leading Particulars
- Table 7. Equipment Description
- Table 8. SDU Rear Connector Pin Deviations
- Table 9. SCM D-Type Connector Pin Assignment
- Table 10. SDU Functional Interfaces
- Table 11. Special Tools, Fixtures, and Equipment
- Table 12. Consumables
- Table 13. LED Status Indicators Table
- Table 14. Special Tools, Fixtures, and Equipment
- Table 15. Consumables
- Table 16. Special Tools, Fixtures, and Equipment
- Table 17. Consumables
- Table 18. Special Tools, Fixtures, and Equipment
- Table 19. Consumables
- Table 20. Fits and Clearances
- Table 21. Thread Size and Torque Data
- Table 22. Final Torque Data
- Table 23. Special Tools, Fixtures, and Equipment
- Table 24. Consumable Materials
- Table 25. Special Tools, Fixtures, and Equipment
- Table 26. Consumable Materials
- Table 27. Special Tools, Fixtures, and Equipment
- Table 28. Consumables
ABBREVIATED COMPONENT MAINTENANCE MANUAL
1458-A-1101 / 1458-A-1300
Characteristic Specification
• Input voltage (AC)
96 to 122 VAC, 300 to 900 Hz
• Input voltage (DC)
18 to 32.3 VDC
Power consum
ption
300 mA if oper
ated with an external FMPA
400 mA if opera
ted as standalone
Table 6. SCM Leading Particulars
Characteristic Specification
Length 4.75 inches (120.7 mm)
Width 4.00 inches (101.6 mm)
Height 1.00 inch (25.4 mm)
Weight 0.66 pound (0.30 kg)
Mounting information 4 x 0.125 inch (3.18 mm) holes on 3.3 x 3.50 inches
(88.9 mm) spacing, per attachment 1-6 of ARINC
781
Electrical interfaces:
•P
ower/Control interface
ARINC 781
Power requirements +12 volts ±5% (derived from SDU)
(6) Refer to Figure 3 (GRAPHIC 23-15-30-99B-803-A01) for the SDU and Figure 4 (GRAPHIC
23-15-30-99B-804-A01) for detailed information on the physical characteristics of the SDU.
EFFECTIVITY
ALL
23-15-30
Page 23 of 70
5 Oct 2012
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Interim DRAFT for FCC Approval Purposes
Do Not Use for Maintenance
10-Feb-2013