Specifications

referenCe
24 EMPYRE ELITE XT INSTALLATION AND OPERATION MANUAL
How to Correct a Sticking Flapper
How to Check if the Flapper is Sticking
1. Ifthereburnswellwhenloadingdoorisopenbut
dies out when door is closed.
2. If little or no exhaust is present at the chimney when
blower is running. (Open rear door to ensure blower
is running.)
How to Correct a Sticking Flapper
1. Check information to determine if the furnace is
being operated properly.
2. Shut off furnace.
3. Insert wire or hex saw blade through the blower
impellor towards blower exit. Insert wire through pin
hole on top surface of the blower, next to blower exit
mount.
Note:Theapopeningandclosingshouldbeheard
when activated.
4. Turn furnace back on.
5. With blower on, carefully spray lubricant into the
blower for 5 seconds.
Should the Flapper Sticking Problem Persist:
1. Check if furnace is being operated properly.
2. Removeapperunit,checktoensuretheapseals
in the closed position, clean and oil.
How to Remove and Reinstall
1. Disconnect power.
2. Remove blower bolt (use 5/16” socket with long
extension). Pull back on motor to remove.
3. Removeapper(2bolts-use5/16”socket).
4. Inspect apper. Upper tabs on ap must seat in
notches.Whenlayingatwithapclosed,tabsmust
notbehigherthanushwithframesurface.Check
with a straight edge; also check if ap in closed
position makes an air tight seal. Also check ap
opening setting, gap should be 3/8” (10 mm) for
the Empyre Elite XT 100 and 3/4” (19 mm) on the
Empyre Elite XT 200.
5. Generously apply oil to the ap on the sealing
surfaces.
6. Toinstallmakesureapwillnotfalloutofapper
unit. If this is a problem simply apply tape at ap
tabs before installing.
7. Bolttheapperunitintoplace,thenbolttheblower
into place.
Empyre Elite XT 100 - Gap to be - 3/8” (10 mm)
Empyre Elite XT 200 - Gap to be - 3/4” (19 mm)
Flap tab and notch