Specifications

12 EMPYRE ELITE INSTALLATION AND OPERATION MANUAL 2011
INSTALLATION
IMPORTANT :
The installation drawings in this manual are typical layouts shown as examples of types of
layouts only. We recommend that you engage a professional plumbing and heating company to
ensure your installation is suitable for your application, will serve your needs and will conform
to all local codes.
The Pro-Fab Industries warranty covers the Empyre Elite furnace only and does not include
anything outside of the Empyre Elite furnace. Pro-Fab Industries takes NO responsibility for
installations. DO NOT modify this unit in any way. Any modication will void the warranty.
These drawings should help in establishing a list of material required for a typical installation.
All parts should be available from your Empyre Elite provider.
Figure 3 - Return Water Temperature Control
- using a 3 way valve on bypass loop
- 1 pump system
- pump to be ON at all times
Figure 4 - Return Water Temperature Control
- using a mixing valve in bypass loop
- only one pump required
- valve works like thermostat in a car radiator
Figure 5 - Return Water Temperature Control
- using a variable speed pump in bypass
- pump has its own sensor to control speed of pump
-increasesowinbypass
Figure 6 - Simple Connection Forced Air or Radiant and
Hot Water Tank
- using 1 pump
- using one 3 way valve