User guide

Controls at a Glance
bypass: Use to engage/bypass the unit. It will illuminate when the
compressor is in the signal chain. It is true bypass and will pass
signal when bypassed even if the unit is powered o.
ratio: Determines the compression ratio for signals above the threshold.
3:1 - Gentle and transparent.
6:1 - More aggressive compression.
12:1 - Limiting.
Note the threshold raises slightly with higher ratios so that the
output volume is more constant when switching ratios at typical
gain reduction settings. This makes comparing the eect of dierent
ratios more accurate.
input: Controls the level of the signal entering the compressor.
The unit has a xed threshold so higher input settings will result
in increased amounts compression.
mix: Blend between wet(compressed) signal and dry(uncompressesed)
signal. Counter clockwise is dry, clockwise is wet.
attack: Controls the time constant which aects how quickly
gain reduction acts after the signal has exceeded the threshold.
(50us - 50ms) *
release: Controls the time constant which aects how quickly the
gain reduction decreases after the signal drops below the threshold.
(50ms-1s) *
*The attack and release controls are not used when the compressor is in
auto mode. Switch to manual mode for control over attack and release.
output: Controls the overall output level leaving the compressor.