INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING
Brief Description of the Components
ThegasvalveisttedwithamanualHI/LOknobtoallowforman-
ualmodulationofthegasoutletpressuretotheapplianceburner.
The Digital Fireplace Control (DFC) is an automatic gas ignition
systembasedonasinglemicrocontrollercore.Thiscontrolman-
agesallfunctionsrelatedtoignition,amesensingandsupervi-
sion for atmospheric applications.
TheDFCcanbesettoprovidecontinuousorintermittentignition
controlsequencesandamemonitoringwithsafetyshutdownin
case of failure.
The DFC is set up as a stand alone (AC powered system with
batterybackup.SeeLightingInstructionsonpage20andWiring
Diagram on page 28.
Troubleshooting
Before proceeding with the procedures in the following trouble-
shooting table, verify that the power supply (AC/DC adapter) is
presentandthatthebatteriesinsidethereceiverand/oroptional
batterypackarefreshandinstalledwithcorrectpolarity.
Make sure all the connectionsbetween thewire harnessesand
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s rec-
ommended inlet pressure. If necessary adjust the line pressure
regulator.
Iftherecommendedactionsforthefollowingtroubleshootingchart
donothelptoaddresstheproblemconsiderreplacingwiringhar-
nesses.
WARNING:
Any actions performed on the gas valve must be performed
in accordance with this instruction manual. Likewise, any
actions performed on the DFC or other system components
must be done in accordance with the individual component
instructions.
Replacement of components must be performed in accor-
dance with this instructions manual.