Owner`s manual

30816-3-0113Page 26
Labelallwirespriortodisconnectionwhenservicingcontrols.Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Millivoltthermopileisselfpowered,gasvalvedoesnotrequire110
volts.Maximumlengthof20feetof16AWGtoconductorwiresis
tobeusedwithalloptionalcomponents.
Use the two leads (Green and Red wires) to attach optional
components.
Check 750 Millivolt System Operation
Millivoltsystemandallindividualcomponentsmaybecheckedwith
a millivolt meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the remote receiver adjacent to
the gas valve.
Attention: The remote receiver bracket is not used in this
installation.
1. The remote receiver can notbeplacedbehindthegasvalve
andburnerassembly.
2. Whenfacingtheappliance,theremotereceivermustbeplaced
to the rightofthegasvalveandburnerassembly.
NOTICE: Do not let remote control receiver come in contact with
burnerassembly.
On circulating vent-free rebox, install remote control receiver
behindbottomlouver.
Refer to remote control installation and operating instructions for
more details on remote control.
MILLIVOLT WIRING
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150 ° CDUL'EQUIVALENT.
THERMOPILE
GAS VALVE
THERMOCOUPLE
(NATURAL)
OFF
ON
REMOTE
(OPTIONAL) REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLEEDISTANCE
DU RECEPTEUR
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
WIRING DIAGRAM
GAS VALVE
VALVEDE GAZ
REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR
REMOTE CONTROL RECEIVER/
THERMOSTAT/ CONTROLE E
DISTANCE DU RECEPTEUR
H N
VEILLEUSE
PILOT
THERMOCOUPLE
(LPG)
Figure 24