Owner`s manual

30816-3-0113Page 18
Flamesfromthepilot(rearrightbacksideoftheburner)aswell
as the main ame should be visuallychecked as the logset is
installed.
Innormaloperation atfullrateafter10to15minutes,theame
appearanceshouldbesetsofyellowames.
NOTICE:Allameswillberandombydesign,ameheightwillgo
up and down.
Avoidanydraftsthatalterburneramepatterns.Donotallowfansto
blowdirectlyintoreplace.Donotplaceablowerinsidetheburner
areaoftherebox.Ceilingfansmaycreatedraftsthatalterame
patterns.Sootingandimproperburningwillresult.
Duringmanufacturing,fabricatingandshipping,variouscomponents
ofthisappliancearetreatedwithcertainoils,lmsorbondingagents.
Thesechemicalsarenotharmful,butmayproduceannoyingsmoke
andsmellsastheyareburnedoffduringtheinitialoperationofthe
appliance,possiblycausingheadachesoreyeorlungirritation.This
is a normal and temporary occurrence.
Theinitialbreak-inoperationshouldlast2-3hourswiththeburner
at the highest setting. Provide maximumventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and willdisappear with
continued use.
PERIODIC CLEANING – Refer to parts diagram for location of
items discussed below.
• Donotusecleaninguidtocleanlogsoranypartofheater.
• Logs- brush with softbristle brush or vacuum with brush
attachment.
• Remove loose particles and dust from the burner areas,
controls, piezo covers and grate.
• Inspectandcleanburnerairintakehole.Removelintorparticles
withbrush.Failuretokeepairintakeholecleanwillresultin
sootingandpoorcombustion.
ANNUAL CLEANING/INSPECTION – Refer to parts diagram for
location of items discussed below.
• Inspectandcleanburnerairintakehole.Removelintorparticles
withvacuumorbrush.Failuretokeepairintakeholecleanwill
resultinsootingandpoorcombustion.
• Inspectandcleanallburnerports.
• InspectODSpilotforoperationandaccumulationoflintatair
intakeholes.
• Verifyamepatternandlogplacementforproperoperation.
• Verifysmoothandresponsiveignitionofmainburner.
OPERATION INSTRUCTIONS/FLAME APPEARANCE
Keepthecontrolcompartment,logsandburnerareasurrounding
thelogscleanbyvacuumingorbrushingareaatleasttwiceayear.
WARNING
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN
COOL.
Alwaysturnoffgastothepilotbeforecleaning.Forrelighting,refer
to lighting instructions located on the rating plate of the log set.
Neverobstructtheowofthecombustionandventilationair.Keep
thefrontofthereplaceclearofallobstaclesandmaterials.
Leaveatleast36"clearancefromthefrontofthereplace.
Screenshouldbeclosedduringoperation.
MAINTENANCE