Dwell - Is the amount of time the solenoid stays on to fire a ball.
Setting the Dwell too high will decrease efficiency. Setting the
Dwell too low will cause inconsistent velocity.
The screen displays the current Dwell time(in milliseconds)
Press RIGHT or Press CENTER of D-Pad to change the Dwell
Time (Default is 18.0 ms)
Press UP or DOWN to increase/decrease the Dwell setting
(2.0-25.0 ms)
Press LEFT or Press CENTER of D-Pad to save setting and return
to CONFIG menu
Pull Debounce (PULL DEB) - Time in milliseconds the trigger
pull must be held to register a valid trigger pull. This eliminates
electronic noise and vibrations that the board may wrongly interpret
as a trigger action (trigger pull) and fire the marker. Too low of a value will cause undesired
trigger pulls. Too high of a value will make it harder to achieve high rates of fire.
The screen displays the current Trigger Pull Debounce setting (in milliseconds)
Press RIGHT or Press CENTER of D-Pad to change the Trigger Pull Debounce setting
(default is 4ms)
Press UP or DOWN to increase/decrease the Pull Debounce setting (1-20 ms)
Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG menu
Release Debounce (REL DEB) - Time in milliseconds the trigger must remain released be-
fore next pull can be registered. Too low of a value will cause undesired trigger
pulls. Too high of a value will make it harder to achieve high rates of fire.
The screen displays the current Trigger Release Debounce setting (in millisec
onds)
Press RIGHT or Press CENTER of D-Pad to change the Release Debounce
setting (default is 6ms)
Press UP or DOWN to increase/decrease the Release Debounce setting (1-20
ms)
Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG
menu
AMB Level - Anti-Mechanical Bounce will help prevent “Run Away”
during sustained firing which is described as the marker shooting
extra shots when the user is not pulling the trigger. A lower value
will make it easier to maintain high rates of fire. A higher value will
prevent “Run Away.”
The screen displays the current AMB Level (adjustable from level
0-10 with level 0 being off)
Press RIGHT or Press CENTER of D-Pad to change the AMB
Level (default is 0)
Press UP or DOWN to increase/decrease the AMB LEVEL setting
(1-10)
Press LEFT or Press CENTER of D-Pad to save setting and return
to CONFIG menu
Ball in Place (BIP) Time - Consecutive milliseconds the Eyes must sense a ball before they
will allow the marker to fire. Increase this setting for slower feeding loaders to avoid chopping
balls in the breech. Decrease this setting for use with faster feeding loaders to increase max
ROF. This setting only has an affect when the eyes are on and not malfunctioning. If not us-
ing a force feed loader a setting of at least 10ms is recommended.
The screen displays the current BIP Time (in milliseconds)
Press RIGHT or Press CENTER of D-Pad to change the Ball In Place setting (default is 5ms)
Press UP or DOWN to increase/decrease the BIP setting (1-20 ms)
Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG menu
Anti-Bolt Stick (ABS) Wait Time – The time in seconds that must expire after
a shot before ABS is activated. This helps prevent first shot drop-off. ABS is a
feature to compensate for stiction of the bolt which causes low velocity on first
shots of a string.
The screen displays the current ABS Wait Time (in seconds)
Press RIGHT or Press CENTER of D-Pad to change the ABS Wait setting
(default is 30s)
Press UP or DOWN to increase/decrease the ABS Wait setting (10-200 sec, in
10 second increments)
Press LEFT or Press CENTER of D-Pad to save setting and return to CONFIG
menu