Manual

7
Example: 10 LED blinks = 12.5 BPS
DWELL SETTING
-WILLBEINDICATEDBYSOLIDAMBERLED
This setting controls the amount of time the solenoid valve is left open. A setting too high will waste
excessgasandaffectefciency.Asettingtoolowwillpreventmarkerfromoperatingproperly.Itisnot
recommended to change this setting unless you are an experienced user. Dwell time is 3.0ms and is
increasedin.5msincrementsupto10ms.UsethechartbelowtosettheDwell.
Default:Dwell=8.0ms
YoumustbeintheSettingsModetochangetheDwellSetting,seeaboveforinstructionsonhowto
enterSettingsMode.AfterchoosingDwellSetting(SolidAmber),holdtheTriggertogetintotheMode,
theLEDwillashAmberLEDblinksequaltothecurrentsetting,followedbyapause.PulltheTrigger
thenumberoftimesequaltoyournewdesiredsetting(seechartbelow).Oncedone,theLEDwill
cycle through an array of colors to indicate the setting is saved and return to the Settings Mode.
TRIGGER DE-BOUNCE
-WILLBEINDICATEDBYAFLASHINGREDLED
Time in milliseconds the Trigger pull must be released before the next Trigger pull can be registered.
Thiseliminateselectronicnoiseandvibrations(“TriggerBounce”)thattheboardmaywronglyinterpret
asaTriggeraction(Triggerpull)andrethemarker.Ahighersettingwillreducethebounce.Alower
settingwillallowformorebounce.Oneblinkcorrespondsto1msofDe-Bouncetime.De-Bounceis
adjustablefrom1-15msin1.0msincrements.
Default:De-Bounce=5.0ms
YoumustbeintheSettingsModetochangetheDe-BounceSetting,seeaboveforinstructionson
howtoenterSettingsMode.AfterchoosingDe-BounceSetting(FlashingRed),holdtheTriggerto
displaythevalue,theLEDwillshowashingRedLEDblinksequaltothecurrentvalue,
followedbyapause.PulltheTriggerthenumberoftimesequaltoyournewdesiredsetting,onepull
per desired setting equal to each millisecond. Once done, the LED will cycle through an array of colors
to indicate the setting is saved and return to the Settings Mode.
BALL IN PLACE (BIP) DELAY
-WILLBEINDICATEDBYAFLASHINGGREENLED
Timeinmillisecondstheballmuststayinbreechbeforeitcanbered.Increasethissettingfor
slower feeding loaders to avoid chopping balls in the breech. Faster force feed loader systems
mayallowforalowersettingtohelpachievehigherratesofre.BIPDelayisadjustablefrom
1-40msin1.0msincrements.
Default:BIPDelay=5.0ms
Note: If you are not using a force-feed loader, it is recommended that you use a higher BIP setting.
YoumustbeintheSettingsModetochangetheBIPDelaySetting,seeaboveforinstructionsonhowto
enterSettingsMode.AfterchoosingBIPDelay(FlashingGreen),holdtheTriggertogetintotheMode,
theLEDwillshowashingGreenLEDblinksequaltothecurrentsetting,followedbyapause.Pullthe
Trigger the number of times equal to your new desired setting, one pull per desired setting equal to each
millisecond. Once done, the LED will cycle through an array of colors to indicate the setting is saved and
return to the Settings Mode.
RAMP START
-INDICATEDBYAFLASHINGAMBERLED
Thissettingcontrolstheamountofsemi-automaticshotsmustberedbeforerampingwillstart.Ifthe
markerisnotredfor1second,thecountwillstartover.RampStartisadjustablefrom1-12shotsin1
shot increments.
Default:RampStart=3Shots
YoumustbeintheSettingsModetochangetheRampStartSetting,seeaboveforinstructionsonhow
toenterSettingsMode.AfterchoosingRampStart(FlashingAmber),holdtheTriggertogetintothe
Mode,theLEDwillshowashingAmberLEDblinksequaltothecurrentsetting,followedbyapause.
PulltheTriggerthenumberoftimesequaltoyournewdesiredsetting,onepullperdesiredsettingequal
to one shot. Once done, the LED will cycle through an array of colors to indicate the setting is saved and
return to the Settings Mode.
RAMP SUSTAIN
-INDICATEDBYAFASTFLASHINGREDLED
ThissettingcontrolstheamountofTriggerpullspersecond(TPS)thatmustbeachievedand
sustainedforramptokickin.RampSustainisadjustablefrom1-12Trigger-pulls-per-second(tps)in1
tps increments.
Default:RampSustain=3tps
YoumustbeintheSettingsModetochangetheRampSustainSetting,seeaboveforinstructionson
howtoenterSettingsMode.AfterchoosingRampSustain(FastFlashingRed),holdtheTriggertoget
intotheMode,theLEDwillshowfastashingRedLEDblinksequaltothecurrentsetting,followedby
apause.PulltheTriggerthenumberoftimesequaltoyournewdesiredsetting,onepullpereach
# LED
BLINKS
DWELL IN
MS
# LED
BLINKS
DWELL IN
MS
1
2
3
4
5
6
7
8
3
3.5
4
4.5
5
5.5
6
6.5
9
10
11
12
13
14
15
7
7.5
8
8.5
9
9.5
10
# LED
BLINKS
BPS
VALUE
# LED
BLINKS
BPS
VALUE
# LED
BLINKS
BPS
VALUE
1
2
3
4
5
6
7
8
9
8
8.5
9
9.5
10
10.5
11
11.5
12
10
11
12
13
14
15
16
17
18
12.5
13
13.5
14
14.5
15
15.5
16
16.5
19
20
21
22
23
24
25
17
17.5
18
18.5
19
19.5
20