Example: 10 LED blinks = 12.5 BPS
DWELL SETTING
-WILLBEINDICATEDBYSOLIDAMBERLED
This setting controls the amount of time the solenoid valve is left open. A setting too high will waste
excessgasandaffectefciency.Asettingtoolowwillpreventmarkerfromoperatingproperly.Itisnot
recommended to change this setting unless you are an experienced user. Dwell time is 3.0ms and is
increasedin.5msincrementsupto10ms.UsethechartbelowtosettheDwell.
Default:Dwell=8.0ms
YoumustbeintheSettingsModetochangetheDwellSetting,seeaboveforinstructionsonhowto
enterSettingsMode.AfterchoosingDwellSetting(SolidAmber),holdtheTriggertogetintotheMode,
theLEDwillashAmberLEDblinksequaltothecurrentsetting,followedbyapause.PulltheTrigger
thenumberoftimesequaltoyournewdesiredsetting(seechartbelow).Oncedone,theLEDwill
cycle through an array of colors to indicate the setting is saved and return to the Settings Mode.
TRIGGER DE-BOUNCE
-WILLBEINDICATEDBYAFLASHINGREDLED
Time in milliseconds the Trigger pull must be released before the next Trigger pull can be registered.
Thiseliminateselectronicnoiseandvibrations(“TriggerBounce”)thattheboardmaywronglyinterpret
asaTriggeraction(Triggerpull)andrethemarker.Ahighersettingwillreducethebounce.Alower
settingwillallowformorebounce.Oneblinkcorrespondsto1msofDe-Bouncetime.De-Bounceis
adjustablefrom1-15msin1.0msincrements.
Default:De-Bounce=5.0ms
YoumustbeintheSettingsModetochangetheDe-BounceSetting,seeaboveforinstructionson
howtoenterSettingsMode.AfterchoosingDe-BounceSetting(FlashingRed),holdtheTriggerto
displaythevalue,theLEDwillshowashingRedLEDblinksequaltothecurrentvalue,
followedbyapause.PulltheTriggerthenumberoftimesequaltoyournewdesiredsetting,onepull
per desired setting equal to each millisecond. Once done, the LED will cycle through an array of colors
to indicate the setting is saved and return to the Settings Mode.
BALL IN PLACE (BIP) DELAY
-WILLBEINDICATEDBYAFLASHINGGREENLED
Timeinmillisecondstheballmuststayinbreechbeforeitcanbered.Increasethissettingfor
slower feeding loaders to avoid chopping balls in the breech. Faster force feed loader systems
mayallowforalowersettingtohelpachievehigherratesofre.BIPDelayisadjustablefrom
1-40msin1.0msincrements.
Default:BIPDelay=5.0ms
Note: If you are not using a force-feed loader, it is recommended that you use a higher BIP setting.
YoumustbeintheSettingsModetochangetheBIPDelaySetting,seeaboveforinstructionsonhowto
enterSettingsMode.AfterchoosingBIPDelay(FlashingGreen),holdtheTriggertogetintotheMode,
theLEDwillshowashingGreenLEDblinksequaltothecurrentsetting,followedbyapause.Pullthe
Trigger the number of times equal to your new desired setting, one pull per desired setting equal to each
millisecond. Once done, the LED will cycle through an array of colors to indicate the setting is saved and
return to the Settings Mode.
RAMP START
-INDICATEDBYAFLASHINGAMBERLED
Thissettingcontrolstheamountofsemi-automaticshotsmustberedbeforerampingwillstart.Ifthe
markerisnotredfor1second,thecountwillstartover.RampStartisadjustablefrom1-12shotsin1
shot increments.
Default:RampStart=3Shots
YoumustbeintheSettingsModetochangetheRampStartSetting,seeaboveforinstructionsonhow
toenterSettingsMode.AfterchoosingRampStart(FlashingAmber),holdtheTriggertogetintothe
Mode,theLEDwillshowashingAmberLEDblinksequaltothecurrentsetting,followedbyapause.
PulltheTriggerthenumberoftimesequaltoyournewdesiredsetting,onepullperdesiredsettingequal
to one shot. Once done, the LED will cycle through an array of colors to indicate the setting is saved and
return to the Settings Mode.
RAMP SUSTAIN
-INDICATEDBYAFASTFLASHINGREDLED
ThissettingcontrolstheamountofTriggerpullspersecond(TPS)thatmustbeachievedand
sustainedforramptokickin.RampSustainisadjustablefrom1-12Trigger-pulls-per-second(tps)in1
tps increments.
Default:RampSustain=3tps
YoumustbeintheSettingsModetochangetheRampSustainSetting,seeaboveforinstructionson
howtoenterSettingsMode.AfterchoosingRampSustain(FastFlashingRed),holdtheTriggertoget
intotheMode,theLEDwillshowfastashingRedLEDblinksequaltothecurrentsetting,followedby
apause.PulltheTriggerthenumberoftimesequaltoyournewdesiredsetting,onepullpereach
# LED
BLINKS
DWELL IN
MS
# LED
BLINKS
DWELL IN
MS
1
2
3
4
5
6
7
8
3
3.5
4
4.5
5
5.5
6
6.5
9
10
11
12
13
14
15
7
7.5
8
8.5
9
9.5
10
# LED
BLINKS
BPS
VALUE
# LED
BLINKS
BPS
VALUE
# LED
BLINKS
BPS
VALUE
1
2
3
4
5
6
7
8
9
8
8.5
9
9.5
10
10.5
11
11.5
12
10
11
12
13
14
15
16
17
18
12.5
13
13.5
14
14.5
15
15.5
16
16.5
19
20
21
22
23
24
25
17
17.5
18
18.5
19
19.5
20