Owner`s manual
32084-3-0813Page 8
OWNER’S MANUAL
Before You Start
1. Verify there is electrical power to the wall furnace.
Verify the Main Power Switch is turned on. See Figure 1.
Figure 1
If electrical power is present, the red and green control board
LED’s will begin to ash alternately. See Figure 3. Each light will
ash four times then the wall furnace will enter standby mode.
While in remote mode, the green LED will ash slowly and the
display panel will show a double dash “ - - “. See Figure 2.
Figure 2
Figure 3
If the control board LED’s do not activate, verify the wall furnace
is plugged in and the breaker is on. If the wall furnace is still not
activated, contact a qualied service technician.
2. Verify the main gas supply to the unit is on.
The shutoff valve should be in the “OPEN” position. See Figure 4.
CLOSED
OPEN
Figure 4
Starting the Wall Furnace
The wall furnace has three modes for controlling operation: Re-
mote, Manual and Local. When in Remote mode, the wall furnace
can be operated by an external thermostat remote control or on/
off wall switch. When in Manual mode, the wall furnace can be
turned on and off and the heat level adjusted manually from the
display panel. When operating in Local mode, the owner sets
a desired room temperature on the display panel and the wall
furnace will automatically turn on and off and adjust the heat level
to achieve the set temperature.
Wall Furnace Operation - Remote Mode (External Thermostat)
To initiate the wall furnace Remote mode, press the “Mode
Select” button on the wall furnace display panel once from OFF
mode to display a double dash “ - - “. See Figure 5.
Figure 5
Notice: When the main power is interrupted, as when following
a power outage, the wall furnace will activate in Remote Mode by
default when power is restored.