SPECIFICATIONS
Models PVS18(N,P) PVS35(N,P)
Maximum Input BTU/HR (KW/H)* 17,500 (5.13) 35,000 (10.26)
Minimum Input BTU/HR (KW/H)* 8,750 (2.56) 17,500 (5.13)
Height 27-7/8” 27-7/8”
Width 36-1/8” 36-1/8”
Depth with Shroud** 13 13
Gas Inlet (Pipe) 3/8” Pipe 3/8” Pipe
Electrical - The wall furnace comes equipped with a 5 foot (1.5m) 3 pronged cord exiting the rear left side of the wall furnace, for con-
nection to an approved 115 VAC, 60 Hz, 15A (maximum) wall receptacle.
Vent Pipe: 1-1/2 or 2 inch diameter pipe, 50 feet maximum equivalent length. See pages 25 and 28 to 31. The vent termination elbow
does not contribute to the overall vent length measurement.
* Input ratings are based on sea level operation and may vary at different elevations. No orice change is required. The appliance will
de-rate automatically 1.5% per 1,000 feet.
** Add 3-3/8 inches for deep shroud.
All vent and combustion air pipes and ttings must be Schedule 40 PVC and meet the ANSI/ASTM Standard D1785. Cement must
conform to ASTM Standard D2564. Empire-approved poly pipe with gasketed joints may also be used. Contact your Empire dealer for
availability.
Listed for Category IV venting.
INTRODUCTION
SPECIFICATIONS AND DIMENSIONS
Dimensions - Figure 22
Approved Alternate Vent Systems
Manufacturer Vent System
Duravent PolyPro
Cetrotherm InnoFlue