Owner`s manual
32084-3-0813Page 14
What tools are needed for installation?
Pipe Wrench
Adjustable Wrench
Drill
Tape Measure
10” x 5/16” Nut Driver
Thread Sealant
Level
2-1/2” Diameter Hole Saw for 2” pipe
2” Diameter Hole Saw for 1-1/2” pipe
1” Diameter Hole Saw
Non-corrosive Leak Check Solution
Where will the wall furnace be installed?
• On the Floor - Wall Furnace comes equipped from
factory for this option. See Page 21.
• Wall Mounted - Wall mount shroud needed. See
Page 15 for kit number.
• Mount wall furnace at a height so that the con-
trols can still be observed.
• Interior Wall - Maximum vent length is 50 feet.
• Exterior Wall
• Locate Electrical Supply - Extension cords may
NOT be used.
• Wall Furnace Dimensions page 16.
• Clearances to Combustibles page 17.
What kind of venting application will be used?
• Single Flue - Wall Furnace comes equipped from
factory for this option. A 2” or 1-1/2” pipe may be
used. If a 1-1/2” pipe is used, it must be enlarged to
a 2” pipe prior to exiting the wall into the shroud.
• Direct Vent - An “Air Pipe Kit” is required and is
available for order. See page 15.
How will the venting be run?
• Straight out the back - Wall Furnace comes
equipped from factory for this option. Standard Rear
Shroud supplied. See page 26.
• In Front of the wall - Deep Shroud needed. Venting
option may NOT be done in Wall Mount installations.
See page 15 for kit number.
• Venting Guidelines pages 24 to 31.
• Maximum vent length is 50 feet.
How will the condensate be disposed?
• To a drain - Wall Furnace comes equipped from the
factory to drain up to 3 feet away from the appliance.
• An Extension Kit and External Condensate Pump
kit may also be used. See page 15 for kit numbers.
• Humidication - Optional Heated Humidication Tray
Kit available for order. See page 15 for kit number.
• Winterization information on page 39.
How will the wall furnace be operated?
• Remote - external thermostat, wall switch or remote
control. See page 15 for kits available from Empire
Comfort Systems.
• Manual - use the display panel to control the heating
level and turn the wall furnace on and off.
• Local (Internal Thermostatic) - Factory installed
temperature probe on the wall furnace with a built-
in thermostatic function to control the wall furnace’s
operation.
• If it is desired to use the temperature sensed in
another part of the room, a wired temperature
probe accessory kit is available. See page 15 for
kit numbers.
• See Operation Instructions pages 7 to 12.
INTRODUCTION