Owner`s manual
32084-6-0214 Page 9
2.  When the external control is activated, the wall furnace dis-
play panel will illuminate and show the heat level along with 
the remote signal symbol. The wall furnace will begin the 
start up sequence automatically. See Figure 6.
Figure 6
Notice: When a Millivolt thermostat or on/off switch is used, the 
wall furnace will only operate on high (Level 5).
Notice: When operating in Remote mode, a button sequence 
may be used to lock the display panel. See page 12.
3.  If a Millivolt thermostat or thermostatic remote is used, set to 
the desired room temperature. The wall furnace will turn on 
and off automatically in response to the thermostat.
Wall Furnace Operation - Manual Mode
Notice:  When operating the wall furnace in Manual mode from 
the display panel, only basic operations are available: On, off and 
heat level adjustment.
1.  To operate the wall furnace in Manual mode, press the “Mode 
Select” button on the display panel twice from off mode until 
a number appears in the Heat Level location on the display 
panel. See Figure 7. The wall furnace will begin the start up 
sequence.
Figure 7
2.  Use the UP and DOWN adjustment buttons on the right of the 
display panel to set the desired level. The display will illumi-
nate and the word “SET” will appear in the top right corner of 
the display. After the level is set, the display panel will darken 
and the heat level will be displayed.
Wall Furnace Operation - Local Mode (Internal Thermostat)
1.  To operated the wall furnace in Local (thermostatic) mode, 
press the Mode Select button on the wall furnace display 
panel three times from the off mode. The display panel will 
show the current room temperature. See Figure 8.
Figure 8
Notice:  The temperature sensing probe is built into the left rear 
of the wall furnace. A kit to relocate the probe is available. See 
page 15.
2.  Use the up and down adjustment buttons on the display 
panel to set the desired room temperature.
  The display will illuminate and the word “SET” will appear 
in the top right corner of the display. See Figure 9. After the 
temperature is set, the display panel will darken and return 
to displaying the room temperature.
Figure 9
3.  When the room temperature drops to 3°F below the set tem-
perature, the wall furnace will begin the start up sequence. 
4.  The wall furnace will automatically adjust the starting level to 
meet the heat demand.
Notice:  The greater the difference between the room and de-
sired temperatures the higher the starting level.
  As the room temperature nears the desired temperature the 
level will decrease.
5.  The wall furnace will turn off if the room temperature rises 
slightly above the set temperature when operating at level 1.
Notice:  The wall furnace will adjust the heat level in order to 
reach a point of equilibrium between the room and desired tem-
peratures. This may cause the wall furnace to operate for long 
periods of time at low levels. 
When the backlight button is pushed, the display will cycle be-
tween the level, set temperature and room temperature.
Notice:  While the wall furnace is operating in Local mode, the 
display will only show the room temperature unless the backlight 
button is pushed.
OWNER’S MANUAL