SPECIFICATIONS
Models PVS18(N,P) PVS35(N,P)
Maximum Input BTU/HR (KW/H)* 17,500 (5.13) 35,000 (10.26)
Minimum Input BTU/HR (KW/H)* 8,750 (2.56) 17,500 (5.13)
Height 27-7/8” 27-7/8”
Width 36-1/8” 36-1/8”
Depth with Shroud** 13 13
Gas Inlet (Pipe) 3/8” Pipe 3/8” Pipe
Electrical - The wall furnace comes equipped with a 5 foot (1.5m) 3 pronged cord exiting the rear left side of the wall furnace, for 
connection to an approved 115 VAC, 60 Hz, 15A (maximum) wall receptacle. The Minimum Circuit Amp (MCA) is 8A, 920W and with 
an accessory heated humidication tray installed, the MCA is 10A, 1150W.
Vent Pipe: 1-1/2 or 2 inch diameter pipe, 50 feet maximum equivalent length. See pages 25 and 28 to 31. The vent termination elbow 
does not contribute to the overall vent length measurement.
* Input ratings are based on sea level operation and may vary at different elevations. No orice change is required. The appliance will 
de-rate automatically 1.5% per 1,000 feet.
** Add 3-3/8 inches for deep shroud.
All  vent and combustion  air  pipes  and  ttings must be  Schedule  40  PVC and meet the ANSI/ASTM  Standard  D1785. Cement must 
conform to ASTM Standard D2564. Empire-approved poly pipe with gasketed joints may also be used. Contact your Empire dealer for 
availability.
Listed for Category IV venting.