Thereboxisdesignedtoaccepta3/8-inchgaslineforanapproved
vent-freegaslogset.Havethelineinstalledbyaqualiedservice
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
exibleapplianceconnectorcannotexceedthreefeetinlength.
Gasaccessholesareprovidedonbothsidesoftherebox.See
Figure 10. On units with ceramic liners installed, carefully remove
the indented knockout in the ceramic brick panel using a drill or
utility knife. See Figure 11.
Checkgastype.Useonlythegastypeindicatedonthegaslog
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
AlwaysuseanexternalregulatorforallLPreboxestoreducethe
supplytankpressuretoamaximumof14"w.c.Thisisinaddition
totheregulatorttedtothelogset.
WARNING:CONNECTIONDIRECTLYTOANUNREGULATED
L.P.TANKCANCAUSEEXPLOSION.
InstallonlyaANSIZ21.11.2vent-freelogsetintothisrebox.
Figure 10
Ifyournon-combustiblefacingmaterialisover1"inthicknessthatwillbeusedtonishthisrebox,anextendedhoodisavailablethatwill
extendout2"fartheroutintotheroom.Contactyourlocaldealerfordetails.
Finishing
Alljoints(top,bottomandsides),wherethewallordecorativefacingmaterialmeetsthereboxsurroundshouldbesealedwithanon-
combustible material.
Hearthextensionsarerecommended,butnotrequiredforthesereboxes.
VB4H32BL Standard Black VB4H36BL Standard Black VB4H42BL Standard Black
VB4H32BR Polished Brass VB4H36BR Polished Brass VB4H42BR Polished Brass
VB4H32SS Stainless Steel VB4H36SS Stainless Steel VB4H42SS Stainless Steel
VB4H32HP Hammered Pewter VB4H36HP Hammered Pewter VB4H42HP Hammered Pewter
GAS ACCESS HOLES
Figure 11
GAS LINE CONNECTION