Owner`s manual
28188-1-0711Page 4
Theclearancefromtheinsideoftherebox
to perpendicular combustible side wall should not be less than
6".Unitmayberecessedasshownonlywithaccessorylinerkit
installed. See Figure 1.
Thereboxoutercasingside
andbackangesarezeroclearancetocombustibles.
Top Framing and Finishing: Combustible framing may rest on
top of standoffs. Combustible nishing materials may extend
to the top standoff screws on the front edge of the outer wrap.
See Figure 2.
Ceiling Clearances:Theceilingheightshouldnotbelessthan42"
from the top of the hood.
Mantel Clearances: Ventfreereboxmodelsmustusethehood
suppliedwiththerebox,oroneoftheoptionalhoodkitsavailable
for each model. If a combustible mantel is installed, it must meet
the clearance requirements detailed below.
Grate Clearance: The minimum clearance between the front legs
ofthegrateandfrontedgeofthereboxis2".
Leaveatleast36"clearancefromthefrontoftherebox.
CLEARANCES
45°
6"
3"
MAX.
PERPENDICULAR
SIDE WALL
FRONT FACE (SIDE)
FIREBOX
(TOP VIEW)
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
WITH ACCESSORY LINER ONLY
MANTEL
STANDARD
HOOD
13”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
11 1/2”
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
10”
22”
8”
20”
6½”
18”
5”
16”
3½”
14”
2”
12 ½”
3/4”
24 ½”
0”
With Accessory Liner Only - Figure 1 Figure 2
Hood
MANTEL
EXTENDED HOOD
(VB4H SERIES)
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
8”
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
10”
22”
8”
20”
6½”
18”
5”
16”
3½”
14 ½”
2½”
24 ½”
0”
16 ½”
FIREBOX
STAND OFF
COMBUSTIBLE
FINISHED WALL
OR MANTEL
2X4
HEADER
TOP OUTER
WRAP
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.