Owner`s manual
28188-1-0711Page 12
A factory installed junction box is located on the lower right
handsideoftherebox.Wiringmustbefedtothejunctionbox
and attached to the receptacle that is provided. Remove the
knockout in the installed junction box to accept wiring into the
junctionbox.InstallaULlistedcableclamp(notsupplied)inthe
knockouthole.Leaveapproximately6"ofwireinthejunctionbox
for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (neutral) screw.
Install the receptacle into the junction box. Attach cover plate.
Keep the control compartment, logs and burner area surrounding the
logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN
COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the log set.
Neverobstructtheowofthecombustionandventilationair.Keep
thefrontofthereboxclearofallobstaclesandmaterials.
Screens must be closed during operation.
Figure 20
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
MAINTENANCE
PARTS LIST
INDEX NO.
PART NUMBER
DESCRIPTION
VFS42FB0F
1 17247 17247 17247 TOP STANDOFF
2 10554 10554 10554 FRAMING BRACKET
3 17162 17162 17162 JUNCTIONBOXASSEMBLY
4 R3492 R3492 R3492 RECEPTACLE
5 R3491 R3491 R3491 COVER,JUNCTIONBOX
6 25101 25101 25101 BLOWER COVER
7 R8213 R8202 R8202 SCREENCURTAIN
8 20020 20145 19984 HOOD
9 R7051 R7052 R7053 ROD, SCREEN
10 R9292 R9292 R9292 HEARTH LEDGE, RIGHT
11 R9293 R9293 R9293 HEARTH LEDGE, LEFT
12 R9294 R9294 R9294 HEARTH LEDGE, CENTER
13 23004 23004 23004 HEARTH RETAINER