Owner`s manual
27061-2-0711 Page 9
Thereboxisdesignedtoaccepta3/8-inchgaslineforanapproved
vent-freegaslogset.Havethelineinstalledbyaqualiedservice
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
exibleapplianceconnectorcannotexceedthreefeetinlength.
Gasaccessholesareprovidedonbothsidesoftherebox.See
Figure 11. On models with ceramic brick panels installed, carefully
remove the indented knockout in the ceramic brick panel using a
drill or utility knife. See Figure 12.
When installing optional ceramic ber side panels into rebox,
laypanelonaatsurface.Removethegaslineknockout(round
depression) in the appropriate side panel using a drill or utility
knife.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
AlwaysuseanexternalregulatorforallLPreboxestoreducethe
supply tank pressure to a maximum of 14" w.c. This is in addition
totheregulatorttedtothelogset.
WARNING: CONNECTION DIRECTLY TO AN UNREGULATED
L.P. TANK CAN CAUSE EXPLOSION.
InstallonlyaANSIZ21.11.2vent-freelogsetintothisrebox.
Figure 11
Extended Hoods
Ifyournon-combustiblefacingmaterialisover1"inthicknessthatwillbeusedtonishthisrebox,anextendedhoodisavailablethatwill
extend out 2" farther out into the room. Contact your local dealer for details.
Finishing
Alljoints(top,bottomandsides),wherethewallordecorativefacingmaterialmeetsthereboxsurroundshouldbesealedwithanon-
combustible material.
Hearthextensionsarerecommended,butnotrequiredforthesereboxes.
VB4H32BL Standard Black VB4H36BL Standard Black VB4H42BL Standard Black
VB4H32BR Polished Brass VB4H36BR Polished Brass VB4H42BR Polished Brass
VB4H32SS Stainless Steel VB4H36SS Stainless Steel VB4H42SS Stainless Steel
VB4H32HP Hammered Pewter VB4H36HP Hammered Pewter VB4H42HP Hammered Pewter
GAS ACCESS HOLES
Figure 12
INSTALLING HOOD (continued)
GAS LINE CONNECTION