Owner`s manual
27061-2-0711 Page 5
Ceiling Clearances: The ceiling height should not be less than 42"
from the top of the hood. See Figures 3a and 3b.
Mantel Clearances: Ventfreereboxmodelsmustusethehood
suppliedwiththerebox,oroneoftheoptionalhoodkitsavailable
for each model. If a combustible mantel is installed, it must meet
the clearance requirements detailed below.
Grate Clearance: The minimum clearance between the front legs
ofthegrateandfrontedgeofthereboxis2".
Leaveatleast36"clearancefromthefrontoftherebox.
MANTEL
STANDARD
HOOD
13”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
11 1/2”
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
10”
22”
8”
20”
6½”
18”
5”
16”
3½”
14”
2”
12 ½”
3/4”
24 ½”
0”
Figure 3a - Mantel Clearances with Standard Hood Figure 3b - Mantel Clearances with Optional Extended Hood
MANTEL
EXTENDED HOOD
(VB4H SERIES)
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
8”
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
10”
22”
8”
20”
6½”
18”
5”
16”
3½”
14 ½”
2½”
24 ½”
0”
16 ½”
CLEARANCES