Owner`s manual

27061-2-0711 Page 13
OPTIONAL SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS
Attention: Install blower assembly before connecting gas inlet
supply line.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external
electrical source is utilized. This appliance is equipped with
a three-prong [grounding] plug for your protection against
shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. For an ungrounded receptacle,
an adapter, which has two prongs and a wire for grounding, can be
purchased, plugged into the ungrounded receptacle and its wire
connected to the receptacle mounting screw. With this wire com-
pleting the ground, the appliance cord plug can be plugged into the
adapter and be electrically grounded.
Caution: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Note: Junctionboxonrightsideofreboxmustbepre-wiredat
timeofreboxinstallationforusewithblowerassembly.A
standard wall ON/OFF wall switch or optional SCV1 Vari-
able Speed Control Kit should be installed to activate power
to the Firebox, and control the operation of the FBB5 Blower
assembly. It is recommended that installation of the wiring
beperformedbyaqualiedelectrician.See Figure 25.
1. Ifinstalled,turnOFFgassupplytorebox/gaslog.
2. Ifapplicable,turnOFFelectricsupplytorebox.
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALI-
FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH
ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE
MAKING THE ELECTRICAL CONNECTION, MAKE SURE
THAT MAIN POWER SUPPLY IS DISCONNECTED. THE
APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICAL-
LY GROUNDED IN ACCORDANCE WITH LOCAL CODES,
WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70
(LATEST EDITION).
A factory installed junction box is located on the lower right
sideoftherebox.Wiringmustbefedtothejunctionboxand
attached to the receptacle that is provided. From right side
of the rebox, remove the screw securing the junction box
assembly. Leave approximately 6” of wire in the junction box
for connection.
Attach black wire to one side of the receptacle and white wire
to opposite side of receptacle. The ground wire should be at-
tached to the green (ground) screw.
Install the receptacle into the junction box. Attach cover
plate.
Attention: If installed, do not damage gas inlet supply line
whenblowerassemblyisinsertedintorebox.Insomecases,
removal the gas inlet supply line may be necessary.
3. Determinewhichtypeofreboxyouhavepriortoinstallation.
See Figures 26 and 27.
Figure 25
REMOVE BOTTOM LOUVER TO
INSTALL BLOWER ASSEMBLY
Figure 26
REMOVE COVER PLATE TO
INSTALL BLOWER ASSEMBLY
Figure 27
Premium Louvered
Models
Premium Flush Face
Models