Specifications
Model VFP30CA30(B,F,M,S,W)
Input BTU/HR (KW/H) Maximum
32,000 (9.4)
BTU/HR (KW/H) Minimum
22,400 (6.6)
Height 27 3/4" (704.9 mm)
Width 28 1/16" (712.8 mm)
Depth 17 1/8" (435.0 mm)
Gas Inlet (Pipe) 3/8" (9.5 mm)
Clearances
In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper opera-
tion.
Locating the Vent Free Cast Iron Stove
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Top of appliance (ceiling) 36 inches Heater Corners (45° angle) to Wall 4 inches
Rear Wall 2 inches Floor 0 inches
Side Wall 6 inches
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
Installation on Rugs and Tile
This appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the oor, or it may
be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, vinyl, woodooring or other
combustible material.
6” (153mm) TO SIDE WALL
OR COMBUSTIBLE
MATERIAL
36” (91cm) TO CEILING OR
HORIZONTAL PROJECTION
ABOVE APPLIANCE