Owner`s manual

32925-3-0115 Page 25
Figures 37 and 38 showacorrectpilotamepattern.Thecorrect
amewillbeblueandwillextendbeyondthethermocouple.The
ame will surroundthe thermocouple just below the tip.A slight
yellowamemayoccurwherethepilotameandmainburnerame
meet. Figures 39 and 40 show an incorrectpilot ame pattern.
Theincorrectpilotameisnottouchingthethermocouple.Thiswill
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Figure 37
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Figure 38
Ifpilotamepatternisincorrect,asshownin Figure 38:
• SeeMillivoltTroubleshooting,page30.
PILOT FLAME CHARACTERISTICS
PILOT
SENSOR
IGNITOR
Figure 39
PILOT
SENSOR
IGNITOR
Figure 40
Ifpilotamepatternisincorrect,asshowninFigure 40:
• SeeIPTroubleshooting,pages38-40.
Flamesfromthepilot(frontcenterofburner)aswellasthemain
ameshouldbevisuallycheckedasthereplaceisinstalled.
Innormaloperationatfullrateafter10to15minutes,theame
appearanceshouldbesetsofyellowames.
Notice:Allameswillberandombydesign,ameheightwillgo
up and down.
Avoidanydraftsthatalterburneramepatterns.Donotallowfansto
blowdirectlyintoreplace.Donotplaceablowerinsidetheburner
areaoftherebox.Ceilingfansmaycreatedraftsthatalterame
patterns.Sootingandimproperburningwillresult.
Duringmanufacturing,fabricatingandshipping,variouscomponents
ofthisappliancearetreatedwithcertainoils,lmsorbondingagents.
Thesechemicalsarenotharmful,butmayproduceannoyingsmoke
andsmellsastheyareburnedoffduringtheinitialoperationofthe
appliance,possiblycausingheadachesoreyeorlungirritation.This
is a normal and temporary occurrence.
Theinitialbreak-inoperationshouldlast2-3hourswiththeburner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
Oncethebreakinoperationhasbeencompleted,adjusttheheater
to the desired output and then replace the surround.
OPERATION INSTRUCTIONS/FLAME APPEARANCE