Owner`s manual
32273-4-1214 Page 9
where the unit is to be installed and whether optional accessories
are desired. Gas supply piping should also be planned at this time.
2. A raised platform non-combustible material.
perimeter edges on the bottom of the unit.
(Example: Four concrete masonry blocks.)
or wood panel extending the full width and depth of the unit.
At this point, you should have decided what components to include
has not been done, stop and consult your dealer for assistance
with this planning.
ventilated space and shall NOT be used in a building, garage, or
other enclosed area.
soot. These issues are nuisance issues rather than a safety issues.
Typical installation may include covered patio, screened porch,
gazebo or an outside wall of a house.
Minimum porch area – 96 square feet
Minimum ceiling height – 92 inches
Do not install appliance until all necessary provisions are made
for combustion and ventilation air. Consult the written instructions
provided with the appliance for information concerning combustion
and ventilation air. In the absence of instructions, refer to the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion
and Ventilation, or applicable local codes.
Television Considerations
Installing a television above an appliance has become increas-
ingly popular; however, the area above any appliance gets hot and
most TV manufacturers recommend against placing their products
near a heat source.
If you install a television above this appliance, Empire Comfort
Systems accepts no responsibility for damage or injuries. Follow
any recommendations regarding proximity to heat sources.
If you have a TV above your appliance, turn off the appliance and
let it cool completely before servicing or touching any buttons on
the TV.
Installation must conform with one of the following conditions:
With walls on all sides, but with no overhead cover;
Within a partial enclosure which includes an overhead cover
and no more than two side walls. These side walls may be
parallel, as in a breezeway or at right angles to each side; or
Within a partial enclosure which includes an overhead cover
and three sidewalls, as long as 30% or more of the horizontal
periphery of the enclosures is permanently open.
appliance and/or accessory are rated for use up to 50,000 Btu
instructions that came with the appliance or accessory (i.e.
clearances, combustion and ventilation air, and enclosure
information).
WARNING
Improper installation, adjustment, alteration, service or mainte-
nance can cause property damage, personal injury or loss of life.
service agency or the gas supplier.
Figure 4
where studs are to be placed.
Figure 5
PLANNING INSTALLATION