Owner`s manual
32273-4-1214Page 12
person in accordance with all building codes. Consult local building
codes to properly size the gas supply line leading to the 3/8-inch
hook-up at the unit. The state of Massachusetts requires that a
See
Figure 12. Carefully remove the knockout in the refractory brick
panel using a large standard screwdriver and hammer. First, place
screwdriver in groove next to plug and pry sideways to pop out
main plug. Then remove the remaining concrete in hole with gentle
tapping with ball peen hammer and/or screwdriver. A masonry drill
and bit may also be used to create a clean hole for the gas line to
pass through.
screwdriver to punch out the metal knockout.
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
supply tank pressure to a maximum of 14" w.c. This is in addition
Install only a ANSI Z21.97.1/CSA 2.41 ventless log set into this
Figure 12
GAS LINE CONNECTION
Figure 13
GAS ACCESS HOLES