Owner`s manual
26284-3-0813 Page 7
Before installing in a solid fuel burning replace, the chimney ue
and rebox must be cleaned of soot, creosote, ashes and loose
paint by a qualied chimney cleaner.
1. Center the gas log in the replace or rebox. The grates must
clear the replace or rebox screen.
2. An anchor hole is provided in the two bottom side members of
the grate frame. After centering the grate correctly, mark the
hole positions on the replace/rebox oor. Drill two (2) 5/32"
diameter holes approximately 1-1/2" deep for masonry screws
or 1/8" hole for sheet metal screws.
3. Anchor the grate to the replace/rebox oor using the screws
provided.
-
BEFORE FULLY INSTALLING THE APPLIANCE
FOR FACTORY BUILT FIREPLACES
-
-
PLIANCES FOR INSTALLATION IN SOLID FUEL BURNING
20 30 40 50 60 70 80
Chimney
Height*
(ft)
10 11.3 16.6 22.1 28.3 35.3 44.2 -
15 8.6 12.6 17.3 21.2 26.4 32.2 31.2
20 7.5 10.8 14.5 18.1 22.1 26.4 31.2
25 6.6 9.6 12.6 15.9 18.1 22.9 27.3
30 6.2 9.1 11.3 14.5 17.3 20.4 24.6
35 5.7 8.0 10.8 13.2 15.9 18.9 22.1
40 5.3 7.5 10.2 12.6 15.2 18.1 20.4
5.9 8.8 11.7 14.6 17.6 20.5 23.4
Chimney
Height*
(m)
3.05 72.9 107.1 142.6 182.6 227.8 285.2 -
4.57 55.5 81.3 111.6 136.8 170.3 207.8 248.4
6.10 48.4 69.7 93.6 116.8 142.6 170.3 201.3
7.62 42.6 61.9 81.3 102.6 116.8 147.8 176.1
9.14 40.0 58.7 72.9 93.6 111.6 131.6 158.7
10.67 36.8 51.6 69.7 85.2 102.6 121.9 142.6
12.19 34.2 48.4 65.8 81.3 98.1 116.8 131.6
* Height is from hearth to top of chimney and the minimum height is
10 feet (3.05m).
** Chart shows minimum opening (sq. in.) (cm
2
) for given height and
input rate.
-
-
20 30 40 50 60 70 80
Chimney
Height*
(ft)
6 17.6 25.7 33.8 41.7 49.2 56.6 64.0
8 16.5 23.7 31.2 38.7 45.5 52.4 59.7
10 15.1 21.7 28.7 35.2 41.7 48.2 54.3
15 14.1 19.9 26.1 32.0 37.7 43.2 48.8
20 12.9 18.5 23.7 28.8 34.3 39.8 44.4
30 12.2 16.9 21.6 26.5 31.2 35.9 40.3
5.9 8.8 11.7 14.6 17.6 20.5 23.4
Chimney
Height*
(m)
1.83 113.6 165.8 218.1 269.0 317.4 365.2 412.9
2.44 106.5 152.9 201.3 249.7 293.6 338.1 385.2
3.05 97.4 140.0 185.2 227.1 269.0 311.0 350.3
4.57 91.0 128.4 168.4 206.5 243.2 278.7 314.8
6.10 83.2 119.4 152.9 185.8 221.3 256.8 286.5
9.14 78.7 109.0 139.4 171.0 201.3 231.6 260.0
* Height is from hearth to top of chimney and the minimum height is 6
feet (1.83m).
** Chart shows minimum opening (sq. in.) (cm
2
) for given height and
input rate.