Owner`s manual

28096-18-0115 Page 7
This series is design certied in accordance with American National Standard/CSA Standard Z21.97 Outdoor Fireplace, respectively, by
the Canadian Standards Association as a Vented Decorative Appliance and should be installed according to these instructions.
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on
the rating plate is the responsibility of the person and company making the change.
Important
All correspondence should refer to complete Model Number, Serial Number and type of gas.
GENERAL INFORMATION
Gas Inlet ONR/ONI Models 3/8" (9.5mm)
Accessories for ONR Models
Battery Operated Remote Control FRBC
Wall Switch FWS
Minimum Dimensions For Solid Fuel Burning Fireplaces
Model A B C D
ONR-24 27" 18" 34" 22"
ONI-24 27" 18" 34" 22"
ONR-30 30" 18" 36" 22"
ONI-30 30" 18" 36" 22"
The dimensions shown and dened in the replace instructions
are minimum clearances to maintain in installing this heater. Left
and right clearances are determined when facing the front of the
heater.
Glass Doors
Make sure that glass doors are open during all operations of
the logset. The opening of the glass door frame should be the
dimension used for the minimum front opening of the rebox.
Follow these instructions to ensure safe installation.
Failure to follow instructions exactly can create a re hazard.
CLEARANCES
2. Ventilation opening(s) shall be provided at oor
level and shall have a total free area of not less
than 1/2 square inch per pound (3.2 sq. cm/kg) of
stored fuel capacity and not less than a total free
area of 10 square inches (64.5 sq. cm). If ventila-
tion openings at oor level are in a side alll, there
shall be at least two openings. The bottom of the
openings shall be at oor level and the upper edge
no more than 5 inches (127 mm) above the oor.
The openings shall be equally sized, spaced at 180
degrees (3.14 rad) and unobstructed.
3. Every opening shall have minimum dimensions so
as to permit the entrance of a 1/8 inch (3.2 mm)
diameter rod.
INTRODUCTION
Cylinder valves shall be readily accessible for hand opera-
tion. A door on the enclosure to gain access to the cylinder
valves is acceptable, provided it is non-locking and can be
opened without the use of tools.
There shall be a minimum clearance of 2 inches (51 mm)
between the lower surface of the oor of the LP-gas supply
cylinder enclosure and the ground.
The design of the appliance shall be such that (1) the LP-gas
supply cylinder(s) can be connected, disconnected and the
connections inspected and tested outside the cylinder en-
closure; and (2) those connections which could be disturbed
when installing the cylinder(s) in the enclosure can be leak
tested inside the enclosure;