Owner`s manual

28096-18-0115 Page 17

1. Match will not light pilot.
a. Main shut-off valve closed.
Make sure that the shut-off valve located on the pipe
supplying gas to the replace is open.
b. Air in the gas line.
Light a match, turn valve knob to "PILOT" position and
depress, keep match near pilot burner until it lights.
c. Valve knob in "OFF" position.
Turn valve knob to "PILOT" position and depress, keep
match near pilot burner until it lights.
d. Pilot orice plugged up, not allowing gas to ow.
This repair requires tools and some degree of experience.
Ask serviceman for assistance.
e. No gas supply to the replace.
Check plumbing to see if gas replace has been hooked
up to the gas supply line.
Propane tanks is empty.
2. Pilot will not stay lit after carefully following lighting instruc-
tions for Models.
a. Defective pilot generator (thermopile), remote wall switch.
Check pilot ame. Must impinge on thermopile. Clean
and or adjust pilot for maximum ame impingement on
thermopile.
Be sure wire connections from thermopile at gas valve
terminals are tight and thermopile is fully inserted into
pilot bracket.
One of the wall switch wires may be grounded. Remove
wall switch wires from valve terminals if pilot now stays
lit, trace wall switch wiring for ground. May be grounded
to appliance or gas supply.
Check thermopile with millivolt meter. Take reading at
thermopile terminals of gas valve. Should read 325 mil-
livolts minimum while holding valve knob depressed in pilot
position and wall switch "Off." Replace faulty thermopile
if reading is below specied minimum.
b. Defective automatic valve operator — Turn valve knob to
"On." Place wall switch to "On" millivolt meter should read
greater than 100 M.V. If the reading is okay and the burner
does not come on, replace the gas valve.
3. Pilot burning, no gas to burner, valve knob "On," wall switch
"On."
a. Wall switch or wires defective.
Check wall switch and wires for proper connections.
Jumper wire cross terminals at wall switch, if burner
comes on, replace defective wall switch. If okay, jumper
wires cross wall switch wires at valve, if burner comes
on, wires are faulty or connections are bad.
b. Thermopile may not be generating sufcient millivoltage.
Replace.
c. Plugged burner orice.
Check burner orice for debris and remove.
4. Frequent pilot outage problem.
a. Pilot ame may be too low or blowing (high) causing the pilot
to drop out.
Clean and/or adjust ame for maximum ame impinge-
ment on thermopile or thermocouple.
TROUBLESHOOTING