Owner`s manual

27825-7-1212 Page 11
1. Place replace in framing opening.
2. Using the four (4) nailing anges provided with the replace,
attach two (2) anges on each side. Attach anges through
prepunched holes. Additional hole locations will be used for
different nishing material with thicknesses of 1/2”, 5/8” and
3/4”. Attach these anges with screws provided, two (2) per
nailing ange.
3. Nailing anges should t directly against non-combustible
framing material. Use at least one (1) nail per tab to secure in
place.
STEEL STUD OR STEEL
FRAMING REQUIRED.
COMBUSTIBLE MATERIAL
NOT ALLOWED ADJACENT
TO FIREPLACE.
NOTE: FINISH MUST BE
CONCRETE BOARD OR
NON-COMBUSTIBLE MA
TERIAL.
OLP36FP OLP42FP
"A" 38 1/2" 38 1/2"
"B" 40" 44"
"C" 19 3/8" 19 3/8"
Attention: Add 1" to "A" Dimensions when using drain tray.
Figure 8
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of steel stud or steel framing material.
Note: Finish must be concrete board or noncombustible material.
SCREW
OR OTHER SUITABLE FASTENER
Figure 6
NON-COMBUSTIBLE
FINISHED WALL
OR MANTEL
2 X 4
NON-COMBUSTIBLE
HEADER
12”
MIN.
Figure 7
FIREPLACE FRAMING AND INSTALLATION