Owner`s manual
27825-7-1212 Page 11
1. Place replace in framing opening.
2. Using the four (4) nailing anges provided with the replace,
attach two (2) anges on each side. Attach anges through
prepunched holes. Additional hole locations will be used for
different nishing material with thicknesses of 1/2”, 5/8” and
3/4”. Attach these anges with screws provided, two (2) per
nailing ange.
3. Nailing anges should t directly against non-combustible
framing material. Use at least one (1) nail per tab to secure in
place.
STEEL STUD OR STEEL
FRAMING REQUIRED.
COMBUSTIBLE MATERIAL
NOT ALLOWED ADJACENT
TO FIREPLACE.
NOTE: FINISH MUST BE
CONCRETE BOARD OR
NON-COMBUSTIBLE MA
TERIAL.
OLP36FP OLP42FP
"A" 38 1/2" 38 1/2"
"B" 40" 44"
"C" 19 3/8" 19 3/8"
Attention: Add 1" to "A" Dimensions when using drain tray.
Figure 8
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of steel stud or steel framing material.
Note: Finish must be concrete board or noncombustible material.
SCREW
OR OTHER SUITABLE FASTENER
Figure 6
NON-COMBUSTIBLE
FINISHED WALL
OR MANTEL
2 X 4
NON-COMBUSTIBLE
HEADER
12”
MIN.
Figure 7
FIREPLACE FRAMING AND INSTALLATION