Owner`s manual

29898-8-1114 Page 31
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external
electrical source is utilized. Thisappliance isequippedwitha
three-prong[grounding]plugforyourprotectionagainstshock
hazardandshouldbepluggeddirectlyintoaproperlygrounded
three-prongreceptacle.Donotcutorremovethegrounding
prongfromthisplug. For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected
to the receptacle mounting screw. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
BlowerMotor
The blower motor does not have oiling holes. Do not attempt to oil
the blower motor.
BlowerWheels
The blower wheels will collect lint and could require periodic cleaning.
If the air output decreases or the noise level increases, it indicates
a dirty blower wheel. Remove blower and clean blower wheels.
WARNING:
Unpluggingofbloweraccessorywillnotstoptheheater
fromcycling.Toturnoffgastotheunventedheater:Push
ingascontrolknobslightlyandturnclockwiseto“OFF.”
Donotforce.
Figure 26
Figure 27
WHITE
WHITE
SPEED CONTROL
FAN
SWITCH
GROUND
110 VOLT AC
JUNCTION BOX
BLACK
FAN
BLACK
5
2
3
4
1
5
1 FBB4 BLOWER ASSEMBLY
COMPLETE
2 R7649 FAN CONTROL
3 R4192 SPEED CONTROL KNOB
4 R4186 SPEED CONTROL
OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS (continued)