Owner`s manual
29898-8-1114Page 30
FBB4BlowerInstallation
Attention: Install blower assembly before connecting gas inlet
supply line.
Note: Junction box on right side of replace must be pre-
wired at time of replace installation for use with blower
assembly. It is recommended that an ON/OFF wall switch
be installed that will activate the power supply to the
furnace by a qualied electrician. See page 32 for junction
box wiring instructions
1. If installed, turn OFF gas supply to replace.
2. If applicable, turn OFF electric supply to replace.
3. Lower bottom louver on replace.
Attention: If installed, do not damage gas inlet supply line when
blower assembly is inserted into replace. If necessary, removal
of the gas inlet supply line may be necessary.
4. Insert blower assembly into interior, bottom of replace. Position
blower assembly behind gas valve, align notch on back of blower
assembly with center screw on replace back and push blower
assembly against replace back. The blower wheel must be
centered with the back wall of the replace. Place blower assembly
against the back wall. The magnets on the back and bottom of
blower assembly will sufciently hold blower assembly in place.
5. Position speed control box to the right of gas valve. Attach speed
control box to bottom of replace. The magnets on the bottom
of speed control will sufciently hold the speed control box in
place.
6. With base (ush face) of fan control switch facing upward, insert
base anges of fan control switch under the mounting tabs on
valve bracket. The base (ush face) of fan control switch must
be in contract with bottom of the rebox.
7. Insert power cord plug into junction box.
8. Close bottom louver on replace.
Note: This blower is equipped with a heat activated fan control
switch. Fan will operate when the replace warms up, and will
turn off when the replace cools down.
9. Installation of FBB4 optional variable speed blower assembly is
completed.
Figure25
VALVE BRACKET
F
AN SWITCH
FAN KIT
SPEED CONTROL
JUNCTION BOX
SWITCH HOLDER
(TOP OF VALVE BRACKET)
SEE NOTE
OPTIONAL BLOWER
INSTA LLATIONIS
INTENDEDFOR
LOUVERED MODELS
ONLY.