Owner`s manual
29898-8-1114 Page 15
1. Place replace in framing opening.
2. Using the four (4) nailing anges provided with the replace,
attach two (2) anges on each side. Attach anges through
prepunched holes. Additional hole locations will be used for
different nishing material with thicknesses of 1/2”, 5/8” and
3/4”. Attach these anges with screws provided, two (2) per
nailing ange.
3. Nailing anges should t directly against framing material. Use
at least one (1) nail per tab to secure in place.
VFP32BP VFP36BP
"A" 36 1/4" 38 1/4"
"B" 34 1/2" 39 1/2"
"C" 17 7/8" 17 7/8"
Attention: Add 3 3/4" to "A" Dimensions when using ush mantel
base.
Figure 12
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of 2 x 4 lumber or heavier.
NAILOR OTHER SUITABLE FASTENER
Figure 10
Figure 11
FIREPLACE FRAMING AND INSTALLATION