Use and Care Guide
Cut out dimensions
For Model
Width
Depth
24GC4B67A, 24GC4L67A
21.85in
18.70in
30GC5B70C, 30GC5L70A
28.55in
18.70in
34GC5B90A, 34GC5B90C, 34GC5L90A, 36GC5L90I
32.88in
18.70in
36GC5B90S
34.06in
18.70in
Technical Data
Burner configuration
NG
LPG
Nozzles Dia. (mm)
Btu/hr
Nozzles Dia. (mm)
Btu/hr
Wok burner(Triple ring burner)
1.62
12000
1.06
12000
Rapid burner
1.5
10200
0.97
10200
Semi rapid burner
1.14
6000
0.75
6000
Auxiliary burner
0.83
3400
0.56
3400
Different models have different total heat input, please refer to page 3,page 4 & page 5.
Gas Type and working pressure:
NG gas pressure at 4.0 in wc
LPG gas pressure at 10 in wc.
Important safety requirements
Location
The cooktops may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom,
shower room or garage. Before making the cut out in the worktop ensure that there is a minimum
distance of 2.17” between the rear edge of the cooktops and the wall. A minimum distance of 3.94”
must be left between the side edges of the cooktops and any adjacent cabinets or walls. The minimum
distance combustible material can be fitted above the cooktops in line with the edges of the cooktops is
18”. If it is fitted below 18” a space of 1.97” must be allowed from the edges of the cooktops. The
minimum distance combustible material can be fitted directly above the cooktops is 30”. Maximum
depth for the overhead cabinets is 13”. The distance from the front edge of the cooktop to the front edge
of the countertop should be 3.0”.The distance between the closet should be 23.62” (not less than the
depth of the cooktop itself) (see Figure 12)
Notice that a horizontal separation below the base of the hotplate is needed.
The minimum distance between this separation shall not exceed 5.90”.