Jumper Definitions
Jumper on center two pins (230V) when no neutral wire is used (240V-dedicated).
Heater Disable Switch Connection. If J29 is shorted by any means, the heater will not run until J29 is no longer shorted.
If J29 is shorted during power-up “J29” will appear on the panel.
The message can be dismissed with a button press, and is the only control panel notification of J29 being shorted.
No message is displayed if J29 is shorted after power-up, but the heater will not run until J29 is no longer shorted.
Non Applicable on UL models
J109 GFCI Test/Trip Enable/Disable
Note: This feature must be enabled in software as well.
J30 Do Not Use
J31
(Used on CE models only)
J29
J29 expects a switch closure (not a voltage) as the command signal.
In some areas, a local power company may offer discounts based on voluntary “power shedding” devices that may be installed in conjunction with the spa.
J25, J26, J27 Heater Type Settings.
Note: Factory Configured do not change.
J44
Two Jumpers installed; one on left 2 pins and one on right 2 pins (115V) when neutral wire is used.
Warning!
Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
J109
J25 J26
J27
J31
115V 115V
230V
J44
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Fixed-fuction DIP Switches
Test Mode (normally Off).
In “ON” position, add one high-speed pump (or blower) with Heater.
In “ON” position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater.
A1
A2
A3
A5
A6
In “ON” position, enables Special Amperage Rule B. See Special Features section under Configuration Options for functionality with your system.
In “OFF” position, enables Special Amperage Rule A.
Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).
A2 and A3 work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e. A2 and A3 in the ON position will
allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the fourth high-speed pump or
blower is turned on.
Note: A2/A3 all off = No heat with any high-speed pump or blower.
Assignable DIP Switches
A4 In “ON” position, enables a 5-minute cooldown for some gas heaters (Cooling Time B).
In “OFF” position, enables a 1-minute cooldown for electric heaters (Cooling Time A).
Undesignated switches are not assigned a function.
DIP Switch Functions
ON
1 6
S1
As soon as Switch #1 is placed
in the ON position, the temperature will show
“T” after it instead of F or C, indicating the
System is in Test Mode
Template 56377 10-05-12
56849-02_56850-02_97_A 11-22-16