Use and Care Manual

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Expansion Features
Control Connection Default Fuse
Relay 1/2 (J108) 1-Speed Pump 2 30A
2-Speed Pump 2 in Setups 11 & 12
Equipment Expansion
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Again, You will have 1 minute to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay
shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup number is showing, press Light once, and the system will reset,
using the newly-selected Setup from that point on.
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very important to any service
person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field.
Changing Software Setups with TP600 / TP400 Continued
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.
THIS SYSTEM IS
CONFIGURED AS
SETUP #
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Waiting time - varies depending on function
SET
Several Setups can
exist in in this string
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
SET
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
A dash (--) indicates the current Setup.
SET
SET
SET
SET
SET
SET
SET
TEST will now appear in
While the Set Temperature is
still flashing, press Light
the LCD first.
SET
RANGE
Main Screen
FLTR
R
READY
ANGE
1
Main Screen
FLTR
R
READY
ANGE
1
SET
Approx.
5 sec.
or
Approx.
5 sec.
or
SET
SET
SET
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
Displays Fault Log
Note: The Timeouts and Spa O/H
selections should NEVER be changed.
They are for safety agency testing
*If the Control Panel does not have a Warm (Up) button, but
rather a single Temp button, use the Temp button in place
of the Warm button in the instruction above. (The flow chart
assumes a single Temperature Button.)
purposes only.
READY
R
ANGE
or
Template 56377 10-05-12
56849-02_56850-02_97_A 11-22-16
Template 56377 10-05-12
56849-02_56850-02_97_A 11-22-16
6