Use and Care Manual
Table Of Contents
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Power Requirements:
240VAC, 50/60Hz*, 48A, Class A GFCI-protected service (Circuit Breaker = 60A max.),
4 wires [hot, hot, neutral, ground]
120/240VAC, 50/60Hz*, 16/40A, Class A GFCI-protected service (Circuit Breaker = 20 /50A max.) - Setups 5 & 10 ONLY,
3 or 4 wires [hot, hot (optional), neutral, ground].
*BP systems automatically detect 50Hz vs 60Hz.
System Ouputs:
Pump 1 240VAC* 2-Speed 15A max 15-minute timer (30-minute timer for low speed)
This is the heater pump
Must deliver 20 GPM through heater
Pump 2 240VAC 1-Speed 15A max 15-minute timer
2-Speed in Setups 11 & 12
Unused in Setups 3, 5, 8 & 10
Pump 3 240VAC 1-Speed 15A max 15-minute timer
Used in Setups 1 & 6 only
Blower 240VAC 1-Speed 4A max 15-minute timer
Used in Setups 2, 3, 7 & 8
.5A maxOzone
Spa Light
240VAC*
10VAC
A/V (Stereo) 120VAC
On/Off
Hot
1A max
4A max
Slaved to Pump 1 low
240-minute timer.
Always on
Heater 5.5kW @ 240VAC max
*Pump 1 and Ozone must be the same voltage.
With 120VAC power input (for Setups 5 & 10 only), Pump 1 and Ozone must be set to 120VAC by moving wires attached to J50 and J51 to area 1 (Neutral).
Basic Functions Setup 1 - 12
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Part # EPN Date Originator Changes Made
56582
56583
56584
4195 01-15-14 BWG BP501G3 initial draft. Adds GFCI Trip (but not GFCI Automatic Test). Updated to latest software version, adding topside-inter-
grated bba™ support.
ZT000148 4467 02-18-15 Customer Spin off custom version of BP501G3 without 2-Speed Pump 2, and adding simplified menus version of eash Setup,
and with new default Setup.
56746 4467 04-01-15 Customer Add two new reminders. Release to production.
56746
56799
4467 10-30-15 Customer Add 4.0kW version.
“ 4752 08-25-16 Customer Change NanTong NBP501X to Canadian Spas CNBP501X, adding Setups for 2 2-speed pumps.
“ 4752 09-05-16 Customer Approved for release, but then retracted, but released anyway due to miscommunication.
56849-01
56850-01
4752 09-28-16 Customer Reconfigure for 3x15A pumps, and change default Setup to Setup 12.
56849-02
56850-02
4817 11-22-16 BWG Updated to latest software version, adding topside-intergrated bba™2 support. Released to production.
System Revision History
bba™ & bba™2 (Balboa Bluetooth Amp) connection is documented seperately.
bba™ is only integrated into graphic display panels (TP800, TP900 and spaTouch™). With TP600 the Aux button operation of bba™ must be used.
bba™2 is only integrated into graphic display panels (TP800, TP900 and spaTouch™). bba™2 does not support Aux button operation.
Template 56377 10-05-12
56849-02_56850-02_97_A 11-22-16
HiPot Testing Note:
Disconnect slip terminal with green
wires from J52 prior to performing
HiPot test. Failure to disconnect may
cause a false failure of the test.
Reconnect terminal to J52 after
successful completion of HiPot test.
Template 56377 10-05-12
56849-02_56850-02_97_A 11-22-16
3