Use and Care Manual
Table Of Contents
- Warnings
- Welcome
- Before you start
- Safety and Warnings
- Safety Symbols
- Electrical Shock Hazard
- Tipping Hazard
- Explosion Hazard
- Fire Hazard
- Poisoning Hazard
- Hot Surface Hazard
- Other Safety Tips
- Stove Models
- HRG 36” Freestanding gas range
- HRG 30” Freestanding gas range
- Gas Supply Requirements
- Safety Tips for Gas Operation
- Dimensions and Clearances
- Electric Power Supply Requirements
- Electrical Grounding Instructions
- 10. First Use
- Conditioning the oven
- Positioning the shelves
- Surface Burner Ignition
- Simmer and Boil
- Flame Size
- Power Failure
- Cooktop
- Burner Grates
- Oven burner use
- Broil burner use
- Oven cooking guidelines
- 12. Oven Function
- Natural Airflow Bake
- Infrared Broil
- Convection Bake
- Convection Roast
- Convection Defrost
- Defrosting
- Convection Dehydration
- 13. Broiler Operation
- Preheating
- To Broil
- Setting Broil
- Broiling guidelines
- 14. Cleaning Instructions
- Do’s
- Don’ts
- Cleaning Burner caps and brass flame spreaders
- Cleaning side racks
- Cleaning oven shelves
- Cleaning broil/roast pan and slotted grid
- Cleaning bake and broil burners
- Cleaning porcelain surfaces
- Cleaning the oven glass window
- Cleaning the oven door gasket
- Cleaning stainless steel surfaces
- 15. Replacing the burner parts
- Removing and replacing the oven door
- Removing the oven door
- Replacing the oven door
- Replacing the oven light bulb
- 16. Troubleshooting Guide
- Cooktop
- Oven
- 17. Warranty & Service
- Warranties and Duration
- Thor Group will pay for:
- Thor Group will not pay for:
- 18. Warranty and Product Registration
- Exhibit A
- Correct Position for Dual Burner
Gas Supply Requirements
22
3. Install male
1
/
2
” or
3
/
4
” (
3
/
4
” refers to 48-inch gas range) flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care to secure the shut-off valve to keep it
from turning.
4. The gas supply pressure for checking the regulator setting is 6 in.w.c. (Nature Gas) and 11
inch.w.c. (LP gas) connect flexible gas line connector to the regulator on the range. Position
range to permit connection at the shut-off valve.
5. When all connections have been made, make sure all range controls are in the position and
turn on main gas supply valve.
6. Leak testing of the appliance shall be conducted according to the manufacturer’s instructions.
Use some soap water (50% water and 50% soap) or a leak detector at all joints and
connections to check for leaks in the system. Do not use a flame to check for gas leaks.
7. The appliance must be isolated from the building’s gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping system at
test pressure equal to or less than
1
/
2
psig(3.5kPa).
After installation:
1. Check ignition of cooktop burners.
2. Check ignition of oven burner.
3. Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are
relighting each time.
4. Check for gas leaks at all gas connections (using a gas detector, never a flame).
5. Check oven bake and convection bake function.