User manual

Specification
MS17/4PIU-6
V10
MS17/6PIU-6
V10
MS17/8PIU-6
V10
MS17/12PIU-6
V10
Number of Inputs 17
Number of Outputs 4 6 8 12
Frequency Range TERR 5-862 MHz (pas), 40-862 MHz (act), SAT 950-2300 MHz
Insertion Loss (avg)
TERR 0/12dB (act
/pas), SAT 0 dB
TERR 0/14dB (act/
pas), SAT 0 dB
TERR 2/16dB (act/
pas), SAT 0 dB
TERR 5/19dB
(act/pas), SAT 0 dB
Isolation (min) 20 dB
Maximum Input
level*
TERR 90/110 dBuV (act/pas),
SAT 90 dBuV
Maximum Output
Level*
TERR 90/98
dBuV (act/pas),
SAT 90 dBuV
TERR 90/96
dBuV (act/pas),
SAT 90 dBuV
TERR 88/94
dBuV (act/pas),
SAT 90 dBuV
TERR 85/91
dBuV (act/pas),
SAT 90 dBuV
Control DiSEqC 2.0
Current Consumption
80 mA (18 V DC) from each satellite receiver
Terr. Input Current 150 mA max (12 V DC)
Power Consumption
7.0 W / 5.0 W (act/pas) + consumption of devices connected to inputs
Dimensions (w,d,h) 47.0 x 15.2 x 8.7 cm (including power supply)
Temperature Range -30°C - +70°C
Specification MS17/16PIU-6
V10
MS17/20PIU-6
V10
MS17/26PIU-6
V10
Number of Inputs 17
Number of Outputs 16 20 26
Frequency Range TERR 5-862 MHz (pas), 40-862 MHz (act), SAT 950-2300 MHz
Insertion Loss (avg)
TERR 7/21dB (act
/pas), SAT 0 dB
TERR 9/24 dB (act
/pas), SAT 4 dB
TERR 10/25 dB
(act/pas), SAT 5 dB
Isolation (min) 20 dB
Maximum Input
level*
TERR 90/110 dBuV (act/pas),
SAT 90 dBuV
Maximum Output
Level*
TERR 83/89 dBuV
(act/pas),
SAT 90 dBuV
TERR 81/86 dBuV
(act/pas),
SAT 86 dBuV
TERR 80/85 dBuV
(act/pas),
SAT 85 dBuV
Control DiSEqC 2.0
Current Consumption
80 mA (18 V DC) from each satellite receiver
Terr. Input Current 150 mA max (12 V DC)
Power Consumption
7 W / 5 W (act/pas) + consumption of devices connected to inputs
Dimensions (w,d,h) 47.0 x 15.2 x 8.7 cm (including power supply)
Temperature Range -30°C - +70°C
* TERR: EN 50083-3/60dB IMA
3
[dBuV]; SAT: EN 50083-3/35dB IMA
3
[dBuV]
avg - average value, there is tolerance of ±4 dB in specified range, min - minimum value, act/pas
- active/passive mode of terrestrial band
10 S ymbols Explanation
certificate of conformity
international standard for digital satellite equipment control, number (1.0, 1.1, 1.2
or 2.0) determines DiSEqC version.
for indoor use only
DC power supply
protective bonding
class II device
fuse protected
safety transformer
According to EU directive, electric and electronic devices which are identified by one
of the following symbols must not be disposed of together with municipal waste. When
disposing of the old device, use local waste collection and separation systems.
11 Wiring Diagrams
7 of 8
2 of 8