Datasheet

======================================================================
Quality Data Inspection
Item Measuring Procedure Standard
1.Appearance Visual check Clean, unscratched
and clearly labeled
2.Dimenaions Measured by calipers with precision of
0.02mm
Max.φ14.5×25.0mm
3.Weight Weighed by balance with precision of 0.1g Max.11g
4.Open-circuit
voltage
Measure by volt-meter with precision of
0.01V
3.65V
5.Operating
voltage
Measure by volt-meter with precision of
0.01V, connecting an impedance of
1200in series, Reaching the target voltage
in 5 seconds.
3.30V
6.Nominal
discharge
1.1K,20±2, Constant discharge to 2.0V. 900mAh
7.Rapid discharge 330,20±2, Constant discharge to 2.0V.. 700mAh
8. Discharge at
high temperature
Put battery in constant ambient temperature
of 55±2 for 16 hours, discharge at 1.1K
to 2.0V/cell..
950mAh
9.Discharge at
low temperature
Put battery in constant ambient temperature
of -40±2 for 16 hours, discharge at 1.1K
to 2.0V/cell
450mAh
10.Charge Prohibited Prohibited
11.Over-discharge Prohibited Prohibited
12.Self discharge Store the batteries at constant temperature
of 20±5, Measure the nominal capacity
yearly for 10 years.
1%