Datasheet

NoteThe data may be different from the above valueif the environmental
temperature is changed
14Cycle Life
Based on clause 7.4.1.1, IEC61951-
2 2003
The charge-discharge cycles
shall exceed 500
times
15Humidity
Standard charge and store for 14
days under the following storage
conditions: 33℃±3(91.4℉±
5.4) Relative humidity of 80%
±5%. (Salting is permitted).
No leakage of electrolyte in
liquid form shall be
observed
16Vibration
Store the cell or battery more than
24 hours after standard charge,
following vibration tests over an
amplitude of 4 mm (0.1575 inches)
at a frequency of 16.7 Hz(1000
cycles per minute) and repeated
through any axes during 60mins。
The subsequent fluctuation of
open circuit voltage and
internal impedance shall be
less than 0.02
V and 5 mΩ
respectively, and the cell or
battery shall not be externally
deformed and no leakage of
electrolyte in liquid form shall
be observed.
17Free falling:
(Drop)
Store the cell or battery more than
24 hours after standard charge,
following a drop test from 450mm
(17.717 inches ) on to a hard-wood
board in a vertical axis 2 times on
each of 2 mutually perpendicular
axes,
The subsequent fluctuation of
open circuit voltage and
internal impedance shall be
less than 0.02 V and 5 m
Ω respectively, and the cell or
battery shall not be externally
deformed and no leakage of
electrolyte in liquid form shall
be observed.
18Short-
circuit testing
to store it for 1 hour after standard
charged, and to make positive and
negative electrode short-circuit with
a wire with the section 0.75mm
2
min
and shortest length, the short-circuit
time is 1 hour
It shall not explode during or
at the end of a 1 hour short-
circuit test. However, leakage
of electrolyte, external
deformation or outer sleeve
cracking is permitted.
19. Safty Valve
Performance
(Over dis-
charging)
to be charged with 1C
mA for 5
hours
safety valve can work
normally, no breakage,
leakage, distortion and out
package breakage are allowed
20. Safty Valve
Performance
(over
charging)
to be charged with 1C mA for 5
hours
No explosion, but leakage,
distortion and out package
breakage are allowed
21.To discharge
at low
temperature
to be stored for 24 hours at 0℃±2
, and discharged at 0.2C
mA at
0℃±2℃。
discharge duration shall
exceed 4
hour
想的更多,做得更好! Think more, do better