Datasheet
Data Sheet
Version: A-0
Page: 6/7
5. Storage and Shipment Requirement
Item. Requirement.
Storage
temperature
within 1 year
-20~+25°C
within 6 month
-20~+35°C
within 1 month
-20~+45°C
within 1 week
-20~+55°C
Humidity
60±15ˁRH
P
lease activate the battery once every 3 months according to the following method: Charge at 0.1C for 14 hrs,
rest
30
min, then discharge with 0.2C to 4.0V/set, rest 30 min, then charge at 0.2C to 150min.
Voltage ~4.8V
6. Scope:
All data involves voltage and weight to stack-up battery are equal to the value of unit cell time the number
of unit cell which consisted in the stack-up batteries
Example˖ Stack-up batteries consisting E unit cells series
Nominal voltage of unit cell=1.2V
Nominal voltage of stack-up batteries =1.2V×4=4.8V
7. Warranty Time.
Warranty time is twelve (12) months from the date when the Nickel-Metal Hydride battery ship out from
. But If the Nickel-Metal Hydride battery is found to have a problem due to use outside
of recommended specification, will have no responsibility for the battery.
8. Others.
Any matters that this specification does not cover should be conferred between both parties.