Datasheet

Document No.:V·LHC-168 Page 2 of 3
1. CHARACTERISTICS
Unless special stated, tests should be carried out within one month of delivery.
Ambient conditions:
Ambient Temperature: 20±5
Relative Humidity: 65±20%RH
Notes: 1)Standard charge/discharge condition
Charge: 140mA(0.1C)×16hours
Discharge: 280mA(0.2C) to 1.0V
2Except special explaining, the battery shall not leakage and PVC shall not breakage during the test.
Test Items Test Conditions Requirements Remark
Capacity Standard Charge and Discharge
Discharge Capacity:
1400 mAh
up to three cycles
are allowed
Internal
Impedance(Ri)
Measure the impedance of battery by
applying AC with frequency of 1000HZ
for not less than 1 hour and not more
than 4 hours after standard charge
20mΩ
Open-circuit
Voltage (OCV)
Voltage between the battery terminals
shall be measured within 1 hour after
standard charge
1.25 V/cell
IEC cycle life IEC61951-2/2011/7.5.1.2 See Remark 1 500 cycles
Self- discharge
Standard charged , stored for 28 days
at standard ambient temperature
Discharge Capacity:
60% original capacity
Over-charge Charge at 140 mA (0.1 C) for 1 year.
No leakage, nor disrupt, nor
burst.
Vibration
resistance
Standard charge. Then leave for 24
hours, check cell before/after vibration.
Amplitude:1.5mm
Vibration:3000CPM
Change of voltage:
ΔV0.02V/ cell
Change of internal impedance
ΔRi5mΩ/ cell
any direction for
60mins
Safety
The Reverse-charge is conducted for 60
minutes at current of 1C after
pre-discharge at 0.2C
current to 0V
The battery shall not explode,
but leakage & deformation are
acceptable
Drop
resistance
After standard charge, rest 24 hours,
check battery before/after drop:
Height: 100 cm
Thickness of wooden board: 30 mm
Change of voltage:
ΔV0.02V/ cell
Change of internal impedance:
ΔR5mΩ/ cell
No breakage except impact
point for PVC sleeves
Direction is not
specified, Test for
3 times
Short Circuit
After standard charge specified in Item
(1), short circuit for 1hour (leading
wire=0.75mm
2
×20mm)
The battery shall not explode,
but leakage & deformation are
acceptable