10. PROCEDURE TO FOLLOW IN THE EVENT OF A BREAKDOWN
CAUTION: NEVER carry out any work on the induction generators without first having disconnected them from the
power supply .
HAZARD: high voltage present in induction generators powered by the electricity supply .
The induction generators should only be opened by QUALIFIED, AUTHORISED PERSONNEL IN COMPLIANCE
WITH INTERNATIONAL, NATIONAL AND REGIONAL SAFETY LAWS AND REGULATIONS.
POSSIBLE CAUSE STEPS TO BE TAKEN
Green LED off
Red LED off.
No power
the power supply
Green LED on
Red LED off.
Make sure you have turned the knob in
a clockwise direction
Turn the knob
Make sure you have positionned the
suitable saucepan correctly
Position a suitable saucepan correctly
Defect control form
Call a technician
Air inlet or outlet blocked. Check and clean air inlet and outlet
Defective fan
Call a technician
Unsuitable saucepan Use a suitable saucepan
Empty cooking protection triggered it to
cool down. The fan is over 220°C.
Verify that the generatur is power
supplied
Cooking point sensor defective
Call a technician
Saucepan diameter under 160 mm
saucepan.
Use a suitable saucepan
Saucepan not positioned correctly and
thus not recognised
Position the saucepan correctly
The power component is too hot and
has switched on the power reduction
automatically
Make sure that the saucepan is suitable.
Internal temperature high due to
insufficient cooling
Unsuitable saucepan Replace with a suitable saucepan
Green LED on
Red LED on
Fast increase in pyroceram
temperature. You may be using an
empty saucepan
Adjust the power on the basis of the
quantity of food
Green LED flashing
Red LED off
Saucepan recognition not correctly
regulated
Call a technician
TYPE OF FAULT
Green LED flashing
Red LED off.
Poor heating
Green LED on
Red LED flashing
No heating
(the power part of the generator is too hot)
Green LED on
Red LED on
Green LED on
Red LED flashing
Heating of small metal objects on the zone
Green LED flashing
Red LED off.
No heating
No heating
(the induction component under the pyroceram is too hot)