Specifications

016
Appendix A - Serial Remote Control (RS232)
XDS1 CD/SACD PLAYER OWNER’S MANUAL
Serial Remote Control (RS232)
e XDS1 is equipped with a 9-pin RS232 port for system remote control via a serial cable
(not provided by EMM Labs). Please use a standard RS232 cable. Do not use a null model
cable, as this will not work. RS232 communication port settings:
• 19,200 baud
• 8 bits
• 1 stop bit
• no ow control
• no parity bit
Commands to the XDS1
All commands sent to the XDS1 consist of 3 ASCII characters (all lowercase) followed by a
carraige return or <CR>. Repeating a <CR> will repeat the last command sent. Received
commands are not stored in a stack. ey need to be sent in intervals of at least 50ms to
allow enough time for the XDS1 to execute a command before receiving the next one.
Command Function
ply Start Playback
pse Pause Playback
stp Stop Playback
mod Toggles through the SACD playback layers. Only works when not playing.
rpt Toggles through the dierent repeat modes
nxt Jumps ahead a track
prv Jumps back a track
© 2012 EMM Labs Inc., All Rights Reserved. EMM Labs reserves the right to amend specifications & design without notice.