Control Messages (cont’d)
Loop (LP) : *PRLP00NA loop OFF
*PRLP01NA loop ON
Display Dim (DM) : *PRDM00NA no dimming, full brightness
*PRDM01NA reduced brightness
*PRDM02NA the backlight is turned o
Volume Display
Units (VU) : *PRVU00NA reserved code
*PRVU01NA the Volume is displayed in Steps (0 to 100)
*PRDM02NA the gain of signal path is shown (in Decibels)
Save settings (SV) : *PRSV00NA product operational settings are saved in non-volatile memory
NULL Cmd. (NL) : *PRNLxxNA where ‘xx’ are any 2 alphanumeric characters; this message is used in system
testing only.
Control Message Timing
Back-to-back command messages can be sent to PRE2 unit, however, no ow control mechanism is used. e longest
recommended data burst is 10 messages. In such a case the burst should be followed by 100ms of idle time. In a real-life