Input Types and Functions
Operation Screen
3-If Actual Value is flashing and counting is stopped ;
It appears if any of the count value is lower than the
minimum count value.
To remove this warning and reset the count value press
RESET button.
2-If Actual Value is flashing and counting is stopped ;
It appears if any of the count value is greater than the
maximum count value.
To remove this warning and reset the count value press
RESET button.
47
S1
SV
O1
OP
S1
SV
O1
OP
S1
SV
O1
OP
S1
SV
O1
OP
RESET
P
SET
RESET
P
SET
RESET
P
SET
RESET
P
SET
7. Specifications
Device Type : Programmable Counter
Housing & Mounting : 96mm x 96mm x 87.5 1/4 DIN 43700 plastic housing for
panel mounting. Panel cut-out is 92x92mm
Protection Class : IP65 at front, IP20 at rear.
Weight : Approximately 0.34 Kg.
Environmental Ratings : Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity
oooo
Storage / Operating Temperature: -40 C to +85 C / 0 C to +50 C
Storage / Operating Humidity : 90 % max. (None condensing)
Installation : Fixed installation
Over Voltage Category : II
Pollution Degree : II, office or workplace, none conductive pollution
Operating Conditions : Continuous