Instructions

44
Output Run Type
Output Normally non-energised
Output Normally energised
Output Pulse Time
It determines how long Output will be active.
It can be adjusted from 00.00 to 99.99 seconds.
If it is 00.00 second, then it operates indefinitely.
For details, refer to the section where output functions are
defined
Data Record
Point Position for Display
Reset and Set Protection (for Front Panel Access)
Only RESET Button protection is active.
Actual value can not be reset by Reset button.
SET value can not be changed.
Full protection ; Reset protection is active and SET value can
not be changed.
No point
Between first and second digits
Between second and third digits
Between third and fourth digits
Between fourth and fifth digits
Count value is saved to memory when power is
disconnected and restored on power up.
Count value is not saved to memory when power is
disconnected. When power up, if the direction is upcounting,
0 value is shown on the screen. If the direction is down
counting then SET value is shown on the screen.
There is no Reset and Set protection