42
Counting direction : P --> 0 (Downcounting)
=
0
Set
Reset
Output
=
0
Set
Reset
Output
Reset Offset
Reset Offset
=
When count value reaches the 0 Value, Output Position is changed. If
Output Pulse time is not 0, then Output Position is changed
at the end of the Pulse time. Counting continue under 0 value. Counting
value becomes SET and output position becomes old position. If output
pulse time ,then output position has not change
until Manual Reset happens.
When Manual Reset happens, if , then count
value becomes SET value. If ,then count value
becomes Reset Offset value.
=
=
=
i
If output functions parameter is selected Automatic Reset (
, or , then must be different from zero
for realizing Automatic Reset.