When count value reaches the SET Value, Output Position is changed.
If Output Pulse time is not 0, then Output Position is changed
the old position at the end of the Pulse time. Count value starts counting
from 0 value. But SET value is observed in actual value display. Real
counting value is shown on Actual value screen at the end of the Output
pulse time. If ,then output position has not changed
until Manual Reset happens. Counting process has not continue over
SET value.
When Manual Reset happens, count value becomes Reset Offset
value.
39
Counting direction : 0 --> P (Upcounting)
=
Automatic Reset-3
0
Set
Reset
Output
0
Set
Reset
Output
=
=
=
Reset Offset
Reset Offset
i
If output functions parameter is selected Automatic Reset (
, or , then must be different from zero
for realizing Automatic Reset.