Instructions

=
=
Counting direction : 0 --> P (Upcounting)
=
35
Manual Reset-3.
Device continues to count till manual reset is applied.
(Output Pulse Time is considered.)
0
Set
Reset
Output
Output
When count value reaches the Set Value, Output Position is
changed. If Output Pulse time is not 0, then Output
Position is changed at the end of the Pulse time. If
then Output Position has not change until Manual Reset happens.
Counting process continues over the SET value.
When Manual Reset happens, count value becomes Reset Offset
value.
=
Counting direction : P --> 0 (Downcounting)
=
0
Reset Offset
Reset
Output
Output
=
=
Set
Reset Offset
=
=
When count value reaches the 0 Value, Output Position is changed. If
Output Pulse time is not 0, then Output Position is changed
at the end of the Pulse time. If ,then Output Position
has not change until Manual Reset happens. Counting process
continues under the 0 value.
When Manual Reset happens; if , then count
value becomes SETvalue, if , then count value
becomes Reset Offset value.
=